DataSheet.es    


PDF LTS15-NP Data sheet ( Hoja de datos )

Número de pieza LTS15-NP
Descripción Current Transducer
Fabricantes LEM 
Logotipo LEM Logotipo



Hay una vista previa y un enlace de descarga de LTS15-NP (archivo pdf) en la parte inferior de esta página.


Total 3 Páginas

No Preview Available ! LTS15-NP Hoja de datos, Descripción, Manual

www.DataSheet4U.com
Current Transducer LTS 15-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 15 At
Electrical data
IPN Primary nominal r.m.s. current
IP Primary current, measuring range
ÎPDC Overload capability
VOUT Analog output voltage @ IP
IP = 0
N S Number of secondary turns (± 0.1 %)
R L Load resistance
R IM Internal measuring resistance (± 0.5 %)
TCRIM Thermal drift of R IM
VC Supply voltage (± 5 %)
IC Current consumption @ VC = 5 V
Typ
Accuracy - Dynamic performance data
X Accuracy @ IPN , TA = 25°C
ε Accuracy with R IM @ IPN , TA = 25°C
L Linearity error
TCVOUT Thermal drift of VOUT @ IP = 0
- 10°C .. + 85°C
- 40°C .. - 10°C
εTC G Thermal drift of the gain
- 40°C .. + 85°C
VOM Residual voltage @ IP = 0,after an overload of 3 x IPN
5 x IPN
10 x IPN
tr a Reaction time @ 10 % of IPN
tr Response time @ 90 % of IPN
di/dt di/dt accurately followed
f Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
General data
TA Ambient operating temperature
TS Ambient storage temperature
m Mass
Standards
15 At
0 .. ± 48
At
250 At
2.5 ± (0.625·IP/IPN) V
2.5 1)
V
2000
2
83.33
< 50
k
ppm/K
5V
28+IS2) +(VOUT/RL) mA
± 0.2
± 0.7
< 0.1
%
%
%
Typ Max
65 120 ppm/K
170 ppm/K
50 3)ppm/K
± 0.5 mV
± 2.0 mV
± 2.0 mV
< 100
< 400
> 35
DC .. 100
DC .. 200
ns
ns
A/µs
kHz
kHz
- 40 .. + 85
°C
- 40 .. + 100 °C
10 g
EN 50178 : 1997
IEC 60950-1 : 2001
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Unipolar voltage supply
Compact design for PCB mounting
Insulated plastic case recognized
according to UL 94-V0
Incorporated measuring resistance
Extended measuring range.
Advantages
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial.
Notes : 1) Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525
2) Please see the operation principle on the other side
3) Only due to TCRIM.
Copyright protected.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
050713/15
Page 1/3
LEM Components
www.lem.com
Tope Co., Ltd. Tel: (02) 8228-0658 Fax: (02) 8228-0659 http://www.sensor.com.tw e-mail: [email protected]

1 page





PáginasTotal 3 Páginas
PDF Descargar[ Datasheet LTS15-NP.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
LTS15-NPCurrent TransducerLEM
LEM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices