DataSheet.es    


PDF HTB100-P Data sheet ( Hoja de datos )

Número de pieza HTB100-P
Descripción Current Transducers HTB 50~400-P and HTB 50~100-TP
Fabricantes LEM 
Logotipo LEM Logotipo



Hay una vista previa y un enlace de descarga de HTB100-P (archivo pdf) en la parte inferior de esta página.


Total 2 Páginas

No Preview Available ! HTB100-P Hoja de datos, Descripción, Manual

Current Transducers HTB 50 .. 400-P/SP5
and HTB 50 .. 100-TP/SP5
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I = 50 .. 400 A
PN
Electrical data
Primary nominal
r.m.s. current
IPN (A)
50
100
200
300
400
Primary current
measuring range
IP (A)
±150
±300
±500
±600
±600
Type
HTB 50-P/SP5, HTB 50-TP/SP51)
HTB 100-P/SP5, HTB 100-TP/SP51)
HTB 200-P/SP5
HTB 300-P/SP5
HTB 400-P/SP5
VC
IC
V
d
R
IS
V
OUT
ROUT
RL
Supply voltage (±5 %)2)
Current consumption
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
Isolation resistance @ 500 VDC
Output
voltage
@
±
I,
PN
R
L
=
10
k,
T
A
=
25°C
Output internal resistance
Load resistance
+12 .. +15 V
<15 mA
2.5 kV
>500
M
V ±1.667 V
OE
100
10 k
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500V
Low power consumption
Primary bus bar option for 50A and
100A version for ease of connection
Accuracy - Dynamic performance data
X
ε
L
VOE
VOH
VOT
εTC G
t
r
f
Accuracy @ I , T = 25°C (without offset)
PN A
<±1 % of I
PN
Linearity (0 .. ± I )
PN
<±1 % of I
PN
Electrical offset voltage, TA = 25°C
Vc/2±30 mV
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
<±0.5 % of IPN
Thermal drift of VOE
HTB 50-(T)P/SP5
<±1.0 mV/K
HTB 100-(T)P..400-P/SP5 <±0.5 mV/K
Thermal drift (% of reading)
<±0.05 %/K
Response time @ 90% of I
P
Frequency bandwidth (-3 dB)3)
<3 µs
DC .. 50 kHz
Special Features
Single power supply from 12V to 15V
Advantages
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
General data
TA Ambient operating temperature
TS Ambient storage temperature
m Mass (-TP version)
-25 .. +85
-25 .. +85
<30 (<36)
°C
°C
g
Notes : EN 50178 approval pending
1) -TP version is equipped with a primary bus bar.
2) Operating at +12V Vc < +15V will reduce measuring range.
3) Derating is needed to avoid excessive core heating at high frequency.
Applications
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
030221/0
LEM Components
www.lem.com

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet HTB100-P.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HTB100-PCurrent Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5LEM
LEM
HTB100-PCurrent Transducers HTB 50~400-P and HTB 50~100-TPLEM
LEM
HTB100-PCurrent Transducers HTB 50~400-P and HTB 50~100-TPLEM
LEM
HTB100-TPCurrent Transducers HTB 50~400-P and HTB 50~100-TPLEM
LEM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar