FS-N10 fiche technique
Digital Fiber Sensor
FS-N10 Series
Instruction Manual
96M00603
Danger
Failure to follow these instructions may lead to death or seri-
ous injury.
Warning
Caution
Failure to follow these instructions may lead to injury.
Failure to follow these instructions may lead to product dam-
age (product malfunction, etc.)
Note Provides additional information on proper operations that can be easily mistaken.
Note
This provides tips about situations in which the feature being described is useful.
Tip
See "FS-N10 Series User's Manual" for details on the features of the FS-N10 series and
detailed instructions for configuration.
Hints on Correct Use
Warning
This product is used to detect targets. Do not apply the
product to safety circuits for human protection.
This product is not of explosion-proof construction. Do not
use the products in places with flammable gas, liquid, or
dust.
This product is a sensor of DC power supply type. Do not
apply AC power. The product may explode or burn if an AC
voltage is applied.
Do not wire the amplifier line along with power lines or high-tension lines, otherwise the sen-
sor may malfunction or receive damage due to noise.
When using a commercially available switching regulator, ground the frame ground terminal
and ground terminal.
Do not use the FS series outdoors, or in a place where extraneous light can enter the light-
receiving surface directly.
Due to the individual dispersion of characteristics and the difference in fiber unit model, the
maximum sensing distance or displayed value of all the units are not the same.
If the sensor is used in S-APC mode for a long time, the LED indicators will be imposed with
a heavy load. In that case, the sensor will be automatically set to ACC mode where the cur-
rent consumption of the sensor for light emission will be constant, and “END APC” will be
displayed. The sensor can be continuously used in this case. Replace the sensor, however, if
highly precise detection is required.
„ About UL Certification
The FS-N series is UL and C-UL certified, and is compliant with the UL and CSA standards.
Applicable standards UL508 Industrial Control Equipment
CAN/CSA C22.2 No.14-M05 Industrial Control Equipment
UL File No. E301717
UL categories: NRKH, NRKH7
Enclosure Type 1 (based on UL50 standard)
„ Notes on UL Certification
The power source used with the FS-N series must be UL Listing certified for Class 2 output
as stipulated by US National Electric Code (NEC) NFPA70.
Connect the FS-N12 and N14 to the FS-N11 and N13 main units for use.
Included accessories
Instruction Manual 1pc.
Fiber cutter
1pc.
FS-N10 Series Quick Start and Cabling
„ Quick Start
Fine sensitivity adjustment
Up Down
Output switch
Press the [MODE] button once, then
use to select L-on or D-on
Setting value Light intensity
Sensitivity setting
Preset function
Configure easily
with a single press
when receiving light
Power select switch *1
Press once each for workpiece/no workpiece
Standard MEGA (fixed)
*1 This is a channel switch on 2-output types.
*2 Press and hold the [MODE] button to make advanced settings.
„ Cabling
Note See page 4 for information about connecting to external devices other than the FS-
N11N.
Mounting Unit
Brown
DC12-24V
Black
Load
Blue
0V
„ Mounting on a DIN Rail
1 Align the claw at the bottom of the main body with
the DIN rail, as shown in figure1.
While pushing the main body in the direction of
the arrow 1, slant it in the direction of the arrow 2.
2 To dismount the sensor, raise the main body in
the direction of the arrow 3 while pushing the
main body in the direction of the arrow 1.
3
2
„ Installation on a Wall (Main Unit Only)
1 Attach the unit to the optional mounting bracket (OP-
73880), mount them together, and secure them with
two M3 screws as shown in figure2.
1
figure1
Connecting Fiber Unit
OP-73880
figure2
1 Open the dust cover in the direction shown by
arrow 1.
2 Move down the fiber lock lever in the direction
shown by arrow 2.
3 Insert a fiber unit into the fiber insertion holes
to a length of the fiber insertion sign (i.e.,
approximately 14 mm).
4 Move down the fiber lock lever in the direction
shown by arrow 4.
4
2
3
1
Fiber insertion sign
Note
If a thin fiber unit is used, an adapter provided with the thin fiber unit will be
required.
Unless the correct adapter is connected, the thin fiber unit will not detect
targets correctly (the adapter is supplied with the fiber unit).
Cable outer dia
1.3
Adapter
Adapter A
(OP-26500)
Appearance
Adapter B
1.0 (OP-26501)
To connect the coaxial reflective type fiber unit to the amplifier, connect the
single-core fiber to the transmitter side, and connect the multiple-core fiber
to the receiver side.
Single-core fiber
Multi-core fiber
Transmitter
Receiver
1

PagesPages 6
Télécharger [ FS-N10 ]


Fiche technique recommandé

No Description détaillée Fabricant
FS-N10 Digital Fiber Sensor Instruction Manual Keyence
Keyence

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche