Rotary Pulse Indicator
K3HB-R
Digital Rotary Pulse Meter Capable of 50 kHz
Measurements
• Measures High-speed Pulses at 50 kHz.
Provides high-speed pulse measurements up to 50 kHz of rotary
encoder or ON/OFF pulse signals and can perform rotating
measurement of high-speed rotating objects.
Note: No-voltage contacts of up to 30 Hz are supported.
• Six Measurement Operations Including Rotation (rpm)/
Circumferential Speed, Ratio, and Cumulative
One Rotary Pulse Meter has 6 rotary pulse measurement functions to
support a variety of pulse measurement applications. Select the best
function for your application from the following: rotation (rpm)/
circumferential speed, absolute ratio, error ratio, error, flow rate ratio,
and passing time.
Refer to Common Precautions on page 30.
Model Number Structure
Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
Base Units with Optional Boards
K3HB-R @
K3HB-R@-@@@
15
1 234 5
1. Input Sensor Codes
NB: NPN input/voltage pulse input
PB: PNP input
5. Supply Voltage
100-240 VAC:100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Optional Board
Sensor Power Supply/Output Boards
K33-@
2
Relay/Transistor Output Boards
K34-@
3
Event Input Boards
K35-@
4
2. Sensor Power Supply/Output Type Codes
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
L1A: Linear current output (DC0(4)-20 mA) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
L2A: Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
A: Sensor power supply (12 VDC ±10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
3. Relay/Transistor Output Type Codes
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
4. Event input Type Codes
None: None
1: 5 points (M3 terminal blocks) NPN open collector
2: 8 points (10-pin MIL connector) NPN open collector
3: 5 points (M3 terminal blocks) PNP open collector
4: 8 points (10-pin MIL connector) PNP open collector
Note: 1. CPA can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator:
RS-232C/RS-485 communications, BCD communications, or DeviceNet communications.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable
4 Rotary Pulse Indicator K3HB-R

1 page




K3HB-R pdf
Function
Operation
F2
Absolute
ratio
Multiples
input
B
divided
by
input
A
(
B
A
)
by
100
and
displays the ratio as a percentage (%).
Display unit: %
Operation image (application)
Measuring the speed ratio between two rollers
HH
H
PASS
L
LL
Warning
F3
Error ratio
Multiplies the error between input A and input B
(B
A
1)
by
100
and
displays
the
ratio
as
a
percentage
(%).
Display unit: %
Measuring the line speed error ratio between two conveyors
Communications
output
(remote monitoring)
To computer
F4 Displays the difference between input A and input B
Rotational (B - A) as the rotation (rpm) speed error or
difference circumferential speed error.
æ Display unit:
ö
ç
ç
ç
rpm, rps, rph,
Hz, kHz, mm/s,
m/s
÷
÷
÷
ç m/min, km/h
÷
è l/min, l/h, etc.
ø
Measuring the rotation (rpm)/circumferential speed error (absolute error)
between two conveyors
HH
H
PASS
L
LL
Warning
F5
Flow rate
ratio
Displays the flow rate ratio of B from inputs A and B
(
B
A+B
)
as
a
ratio
(%).
Display unit: %
Monitoring liquid mixture flow rate ratio
Linear output
Recording meter
F6
Passing
time
Passing time (s) = 1/ƒa × α
ƒa: Input frequency (Hz)
Set the prescale value for the desired display unit using
the following table for reference.
Displaying the passing time for a conveyor line
Calculation Display unit Prescale value (α)
Passing time
s
L/(πd/N)
N = Pulses per rotation
πd = Circumferential length per rotation (m)
L = Length of process (m)
Distance
H
PASS
L
Warning
output
8 Rotary Pulse Indicator K3HB-R

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet K3HB-R.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
K3HB-CDigital Indicators User ManualOmron
Omron
K3HB-CUp/Down Counting Pulse IndicatorOmron
Omron
K3HB-HTemperature IndicatorOmron
Omron
K3HB-PDigital Indicators User ManualOmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar