DataSheet.es    


PDF S-8209A Data sheet ( Hoja de datos )

Número de pieza S-8209A
Descripción BATTERY PROTECTION IC
Fabricantes Seiko Instruments 
Logotipo Seiko Instruments Logotipo



Hay una vista previa y un enlace de descarga de S-8209A (archivo pdf) en la parte inferior de esta página.


Total 27 Páginas

No Preview Available ! S-8209A Hoja de datos, Descripción, Manual

S-8209A Series
www.sii-ic.com
© Seiko Instruments Inc., 2008-2014
BATTERY PROTECTION IC
WITH CELL-BALANCE FUNCTION
Rev.3.5_00
The S-8209A Series is a protection IC for lithium-ion / lithium polymer rechargeable batteries and includes a high-accuracy
voltage detection circuit and a delay circuit.
The S-8209A Series has a transmission function and two types of cell-balance function so that users are also able to configure
a protection circuit with series multi-cell.
Features
High-accuracy voltage detection circuit
Overcharge detection voltage*1
Overcharge release voltage*1
Cell-balance detection voltage*1
Cell-balance release voltage*1
3.55 V to 4.40 V (5 mV step)
3.50 V to 4.40 V*2
3.55 V to 4.40 V (5 mV step)*3
3.50 V to 4.40 V*4
Overdischarge detection voltage
Overdischarge release voltage
2.0 V to 3.0 V (10 mV step)
2.0 V to 3.4 V*5
Settable delay time by external capacitor for output pin
Control charging, discharging, cell-balance by CTLC pin and CTLD pin
Two types of cell-balance function; charge / discharge*6
Wide range of operation temperature
Ta = 40°C to +85°C
Low current consumption
Lead-free, Sn 100%, halogen-free*7
7.0 μA max.
Accuracy ±25 mV
Accuracy ±50 mV
Accuracy ±25 mV
Accuracy ±50 mV
Accuracy ±50 mV
Accuracy ±100 mV
*1. Regarding selection of overcharge detection voltage, overcharge release voltage, cell-balance detection voltage
and cell-balance release voltage, refer to Remark 3 in "3. Product name list" of "Product Name Structure"
*2. Overcharge release voltage = Overcharge detection voltage Overcharge hysteresis voltage
(Overcharge hysteresis voltage is selectable in 0 V to 0.4 V, in 50 mV step.)
*3. Select as to overcharge detection voltage > cell-balance detection voltage.
*4. Cell-balance release voltage = Cell-balance detection voltage Cell-balance hysteresis voltage
(Cell-balance hysteresis voltage is selectable in 0 V to 0.4 V, in 50 mV step.)
*5. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage is selectable in 0 V to 0.7 V, in 100 mV step.)
*6. Also available the product without discharge cell-balance function
*7. Refer to "Product Name Structure" for details.
Applications
Lithium-ion rechargeable battery pack
Lithium polymer rechargeable battery pack
Packages
8-Pin TSSOP
SNT-8A
Seiko Instruments Inc.
1

1 page




S-8209A pdf
Rev.3.5_00
BATTERY PROTECTION IC WITH CELL-BALANCE FUNCTION
S-8209A Series
3. 2 SNT-8A
Product Name
S-8209AAA-I8T1x
S-8209AAB-I8T1x
S-8209AAC-I8T1x
S-8209AAD-I8T1x
S-8209AAF-I8T1x
S-8209AAG-I8T1x
S-8209AAH-I8T1x
S-8209AAJ-I8T1x
S-8209AAK-I8T1x
S-8209AAL-I8T1x
S-8209AAS-I8T1x
S-8209AAT-I8T1x
S-8209AAU-I8T1x
S-8209AAX-I8T1U
S-8209AAZ-I8T1U
S-8209ABA-I8T1U
S-8209ABE-I8T1U
S-8209ABF-I8T1U
S-8209ABG-I8T1U
S-8209ABI-I8T1U
S-8209ABJ-I8T1U
S-8209ABK-I8T1U
S-8209ABL-I8T1U
S-8209ABM-I8T1U
S-8209ABY-I8T1U
S-8209ACE-I8T1U
S-8209ACH-I8T1U
Overcharge
Detection
Voltage
[VCU]
4.100 V
3.800 V
3.900 V
4.250 V
4.250 V
3.900 V
3.900 V
4.275 V
4.300 V
4.250 V
4.220 V
4.325 V
3.600 V
4.300 V
4.250 V
3.900 V
4.200 V
3.850 V
4.250 V
4.250 V
3.900 V
4.275 V
4.215 V
3.800 V
4.230 V
3.600 V
4.300 V
Overcharge
Release
Voltage
[VCL]
4.000 V
3.750 V
3.500 V
4.100 V
4.100 V
3.600 V
3.700 V
4.125 V
4.100 V
4.100 V
4.120 V
4.125 V
3.500 V
4.100 V
4.100 V
3.600 V
4.100 V
3.650 V
4.050 V
4.100 V
3.600 V
4.075 V
4.215 V
3.700 V
4.180 V
3.500 V
4.300 V
Table 3
Cell-balance
Detection
Voltage
[VBU]
4.050 V
3.650 V
3.550 V
4.200 V
4.100 V
3.550 V
3.600 V
4.200 V
4.100 V
4.100 V
4.200 V
4.200 V
3.550 V
4.140 V
4.200 V
3.600 V
4.175 V
3.600 V
4.200 V
4.200 V
3.600 V
4.200 V
4.190 V
3.650 V
4.200 V
3.550 V
4.200 V
Cell-balance
Release
Voltage
[VBL]
4.000 V
3.600 V
3.550 V
4.100 V
4.000 V
3.500 V
3.600 V
4.200 V
4.000 V
4.000 V
4.200 V
4.200 V
3.500 V
4.090 V
4.200 V
3.500 V
4.175 V
3.600 V
4.200 V
4.200 V
3.500 V
4.200 V
4.190 V
3.550 V
4.200 V
3.500 V
4.200 V
Overdischarge Overdischarge Discharge
Detection
Release Cell-balance
Voltage
Voltage
Function
[VDL]
[VDU]
2.50 V
2.70 V
Yes
2.00 V
2.50 V
Yes
2.50 V
2.70 V
Yes
2.50 V
3.00 V
Yes
2.75 V
3.05 V
Yes
2.00 V
2.40 V
Yes
2.50 V
2.80 V
No
2.30 V
2.80 V
Yes
2.50 V
3.00 V
Yes
2.75 V
3.05 V
No
2.50 V
3.00 V
Yes
2.50 V
3.00 V
No
2.20 V
2.50 V
Yes
2.50 V
3.00 V
Yes
2.50 V
3.00 V
Yes
2.00 V
2.70 V
Yes
2.80 V
2.90 V
Yes
2.30 V
2.50 V
Yes
3.00 V
3.00 V
Yes
2.50 V
3.00 V
No
2.00 V
2.70 V
No
2.75 V
2.95 V
No
2.50 V
3.00 V
No
2.00 V
2.50 V
No
2.80 V
3.00 V
No
2.20 V
2.50 V
No
2.50 V
3.00 V
No
Remark 1. x: G or U
2. Please select products of environmental code = U for Sn 100%, halogen-free products.
Seiko Instruments Inc.
5

5 Page





S-8209A arduino
Rev.3.5_00
BATTERY PROTECTION IC WITH CELL-BALANCE FUNCTION
S-8209A Series
CTLC
CB
CTLD
CO
S-8209A Series
VDD
DO
CDT
VSS
AA A
CTLC
CB
CTLD
CO
S-8209A Series
VDD
DO
CDT
VSS
AA
COM
Figure 13 Test circuit 7
COM
Figure 14 Test circuit 8
Seiko Instruments Inc.
11

11 Page







PáginasTotal 27 Páginas
PDF Descargar[ Datasheet S-8209A.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
S-8209ABATTERY PROTECTION ICSeiko Instruments
Seiko Instruments
S-8209BBattery Protection ICSeiko Instruments
Seiko Instruments

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar