DataSheetWiki


GV3P40 fiches techniques PDF

Schneider - motor circuit breaker thermomagnetic trip unit

Numéro de référence GV3P40
Description motor circuit breaker thermomagnetic trip unit
Fabricant Schneider 
Logo Schneider 





1 Page

No Preview Available !





GV3P40 fiche technique
Product datasheet
Characteristics
Complementary
Network frequency
Mounting mode
Mounting support
Mounting position
[In] rated current
Thermal protection adjustment range
Phase failure sensitivity
[Ue] rated operational voltage
[Ui] rated insulation voltage
[Ith] conventional free air thermal current
Network frequency
[Uimp] rated impulse withstand voltage
Power dissipation per pole
Mechanical durability
Electrical durability
GV3P40
motor circuit breaker GV3 poles - 40 A - everlink
BTR screw connectors - thermomagnetic trip unit
Main
Range of product
Device short name
Product or component type
Circuit breaker application
Poles description
Network type
Control type
Motor power kW
Trip unit technology
Magnetic tripping current
Suitability for isolation
Utilisation category
Connections - terminals
GV3P
Thermal magnetic circuit breaker
Thermal magnetic circuit breaker
Motor protection
3P
AC
Rotary knob
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
18.5 kW at 400...415 V AC 50/60 Hz
Thermal-magnetic
560 A
Yes conforming to IEC 60947-1 § 7-1-6
AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
Power circuit: EverLink BTR screw connectors 2
cable 1...25 mm² - cable stiffness: solid
Power circuit: EverLink BTR screw connectors 2
cable 1...25 mm² - cable stiffness: flexible - without
cable end
Power circuit: EverLink BTR screw connectors 1
cable 1...35 mm² - cable stiffness: flexible - without
cable end
Power circuit: EverLink BTR screw connectors 2
cable 1...25 mm² - cable stiffness: flexible - with
cable end
Power circuit: EverLink BTR screw connectors 1
cable 1...35 mm² - cable stiffness: flexible - with
cable end
Power circuit: EverLink BTR screw connectors 2
cable 1...35 mm² - cable stiffness: solid
50/60 Hz
Fixed
Plate
Rail
Horizontal
Vertical
40 A
30...40 A conforming to IEC 60947-4-1
Yes conforming to IEC 60947-4-1 § 7-2-1-5-2
600 V AC 50/60 Hz conforming to CSA C22-2 No 14
600 V AC 50/60 Hz conforming to UL 508
690 V AC 50/60 Hz conforming to IEC 60947-2
690 V conforming to IEC 60947-2
40 A conforming to IEC 60947-4-1
50/60 Hz conforming to CSA
50/60 Hz conforming to IEC 60947-4-1
50/60 Hz conforming to UL
6 kV conforming to IEC 60947-2
8W
50000 cycles
50000 cycles on AC-3 at 440 V In
1/2

PagesPages 2
Télécharger [ GV3P40 ]


Fiche technique recommandé

No Description détaillée Fabricant
GV3P40 motor circuit breaker thermomagnetic trip unit Schneider
Schneider

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche