GOT1000 Series Operator
Terminals
Human-Machine Interfaces
Installation Manual for GT1040-QBBD
and GT1045-QSBD
Art-no.: UK, Version A, 15092009
Safety Information
For qualified staff only
This manual is only intended for use by properly trained and qualified electrical
technicians who are fully acquainted with automation technology safety stan-
dards. All work with the hardware described, including system design, installa-
tion, setup, maintenance, service and testing, may only be performed by
trained electrical technicians with approved qualifications who are fully
acquainted with the applicable automation technology safety standards and
regulations.
Proper use of equipment
The GOT1000 series operator terminals (GT1040 and GT1045) are only intended
for the specific applications explicitly described in this manual or other manu-
als. Please take care to observe all the installation and operating parameters
specified in the manual. All products are designed, manufactured, tested and
documentated in agreement with the safety regulations. Any modification of
the hardware or software or disregarding of the safety warnings given in this
manual or printed on the product can cause injury to persons or damage to
equipment or other property. Only accessories and peripherals specifically
approved by MITSUBISHI ELECTRIC may be used. Any other use or application
of the products is deemed to be improper.
Relevant safety regulations
All safety and accident prevention regulations relevant to your specific applica-
tion must be observed in the system design, installation, setup, maintenance,
servicing and testing of these products.
In this manual special warnings that are important for the proper and safe use
of the products are clearly identified as follows:
P DANGER:
Personnel health and injury warnings.
Failure to observe the precautions described
E CAUTION:
Equipment and property damage warnings.
Failure to observe the precautions described
Further Information
More information about the operator terminals of the GOT1000 series and the
configuration tool GT Designer2 is available free of charge through the internet
(www.mitsubishi-automation.com).
If you have any questions concerning the installation, configuration or opera-
tion of the equipment described in this manual, please contact your relevant
sales office or department.
Dimensions
10
Thread:
#4-40UNC
Thread: M2.6
139
86
10 15.5
10 86 10 17.5
Panel thickness: 5.0 mm or less
129
* with memory board installed
40
RS-232 connection
RS-422 connection
Memory board GT10-50FMB
All dimensions are in "mm".
Panel Cut Out
Shown below is the horizontal format. If the vertical format is selected, the
dimensions must be rotated 90g.
13 or more
A space of at least 13 mm at the
upper and lower side of the GOT
is required to allow for the
attachment of mounting fix-
tures.
130
+1
-0
13 or more
Unit: mm
Distances to other devices
Horizontal format
80 (20)
50 50
(20) (20)
Vertical format
50 (20)
80 50
(20) (20)
50 (20)
Other device or
control panel
Unit: mm
50 (20)
On the back of the GOT a space of at least 100 (20) mm is required.
The values enclosed in parenthesis apply to the case where no other equip-
ment generating radiated noise (such as a contactor) or heat is installed nearby.
Installation and Wiring
P DANGER
b Switch OFF the power supply of the operator terminal before starting
the installation work or wiring and before mounting or removing the
memory board.
b When the communication between the operation terminal and the
PLC fails it is impossible to operate keys or devices via the operation
terminal. Therefore emergency stops and other safety functions must
not be controlled via the PLC.
E CAUTION
b Do not disassemble or modify the unit. Doing so can cause a failure,
malfunction, injury or fire.
b Use the GOT in the environment that satisfies the general specifica-
tions described in this manual. Don't mount the operation terminal in
an enviroment that contains high explosive risks, strong magnetic
fields, direct sunlight or large, sudden temperature changes.
b Never allow fluids, metal filings or wiring debris to enter any open-
ings in the operator terminal. This may cause short circuits and fire.
Mounting
A GOT is designed to be installed into the door of a control cabinet or into a con-
trol panel.
When the temperature inside the control cabinet or
105f
control panel is 40 to 55 °C (Horizontal mount) or 40 to
50 °C (Vertical mount), the mounting angle should be in
GOT the range 60° to 105° degrees.
60f
Prepare a hole in the panel with the dimensions shown on the left. Please
note that the GOT can also be mounted vertically.
Install the packing to the packing
installation groove on the back Packing
panel of the GOT.
Power Supply Wiring
E CAUTION
b Do not lay signal cables close to the main circuit, high-voltage power
lines, or load lines. Otherwise effects of noise or surge induction are
likely to take place. Keep a safe distance of more than 100 mm from
the above when wiring.
b When connecting the power supply please confirm the rated voltage
and the polarity. Not doing so can cause a fire or failure.
Applicable wires and terminal torque
Connect the power supply to the power terminals on the back panel of the
GOT. Use a specified size power supply wire to prevent voltage drop, and
tighten the terminal screws firmly to a torque of 0.22 to 0.25 Nm.
No. of wires per
terminal
Solid wire
1
2
Ground wire
0.14 to 1.5 mm2
0.14 to 0.5 mm2
1.5 mm2
Wire size
Stranded wire
0.14 to 1.0 mm2
0.14 to 0.2 mm2
1.0 mm2
Ferrules with
plastic sleeve
0.25 to 0.5 mm2
0.5 mm2
b Connecting the wire directly
Strip the coating of strand wire and twist the cable
core before connecting it. Do not solder the wire
end. Strip the coating of solid wire before connect-
ing it.
5 mm
b Using of ferrules with plastic sleeve
Refer to the drawing below for how to select the proper size ferrules.
Insulation sleeve
Contact area
2.0 to 2.5 mm
6 mm
10.5 to 12 mm
Magnified
illustration
Insert the GOT from the front of
the panel or the control cabinet
into the cut out.
Packing
Packing
groove
Grounding
Make sure to ground the FG terminal of the GOT. The size for the grounding
wire is given in the above table.
b The grounding resistance should be 100 ȑ or less.
b The grounding point should be close to the GOT. Keep the grounding
wires as short as possible.
b Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared
grounding" of the following figure.
GOT
Other
equipment
GOT
Other
equipment
GOT
Other
equipment
Cut out
Insert the hooks on the mounting
fittings (supplied) into the mount-
ing holes on the GOT unit.
Slide the mounting fittings to the
back end.
Slide them to the left to lock them
in place.
Please use all supplied mounting
fittings and tighten the mounting
screws with a torque of 0.2 to
0.25 Nm.
Mounting Mounting fitting
screw
Independent grounding
Best condition
Shared grounding
Good condition
Common grounding
Not allowed
Connection to the Control System
An operator panel of the GOT1000 series can be connected not only to PLCs
from Mitsubishi Electric but also to inverters, servo amplifiers, CNC as well and
to PLCs from third party manufacturers and many other devices. For further
information please refer to the Connection Manual for the GOT1000 series.
After mounting, remove the protection film from the operator terminal display.
MITSUBISHI Mitsubishi Electric Europe B.V. /// FA - European Business Group ///
ELECTRIC Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-486112 ///
FACTORY AUTOMATION www.mitsubishi-automation.com

PagesPages 12
Télécharger [ GOT1000 ]


Fiche technique recommandé

No Description détaillée Fabricant
GOT1000 Operator Terminals MITSUBISHI
MITSUBISHI

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche