DataSheetWiki

U1660 Datasheet دیتاشیت PDF دانلود

دیتاشیت - GOSSEN METRAWATT - LON-Add-On Component Meter Reading Module

شماره قطعه U1660
شرح مفصل LON-Add-On Component Meter Reading Module
تولید کننده GOSSEN METRAWATT 
آرم GOSSEN METRAWATT 


1 Page

		

No Preview Available !

U1660 شرح
U1660 LON-Add-On Component
Meter Reading Module
• 8 active S0 pulse inputs
required pulse duration > 100 ms
• LED state display
• FTT-10A transceiver (78 kBit/s)
• Standard network variables
for energy, instantaneous power and state
• LED status display
3-349-214-03
2/12.05
QUALITY MANAGEMENT SYSTEM
DQS certifizied per
DIN EN ISO 9001 Reg. No.1262
Applications
Display Elements
The LON add-on component is used for scanning measuring
points within the energy control system in a decentralized fashion.
The U1660 meter reading module processes data from up to 8
energy meters with pulse output (S0), or floating contact. The
active inputs do not require any additional power supply which
minimizes wiring expenses.
The add-on component expands the functions offered by the
U1601 summator, the U1602 micro-summator and the U1603
mini-summator to include external inputs via the LON interface.
Power LED
Active LED
Error LED
Function
U1660 is a meter reading module with eight active inputs. It
determines energy and instantaneous power on the basis of SO
pulses.
The valence of a pulse (delta) is calculated from the meter con-
stant (nciPulseRate). The pulses are counted (nvoEnergyPower)
and converted into energy (nvoEnergy). Instantaneous power
(nvoPower) is calculated from the distance between two pulses.
The network variables nvoEnergyPower, nvoEnergy and
nvoPower are calculated and transmitted after each pulse. The
meter readings (nvoEnergyPower, nvoEnergy) are lost upon auxil-
iary voltage failure.
In addition to energy and power measurement, the state of the
binary inputs is transferred to the network (nvoInputState[8],
nvoAllInState).
M1 bis M8
Controls
Service Sockets
ID Key
On: Operating voltage on
On: S0 inputs are supplied with
voltage. If the adapter is in
unconfigured or offline state,
the LED is off and the SO inputs
are not supplied with voltage.
Signals the state of the LON node
(„Service LED“), is activated for
2 seconds upon receipt of a wink
command.
On: Module has no application
Blinking: Module is not configured
On: Current flow via pulse contact
of the meter
Direct LON bus access for service
applications
Identifies the module in the network
(„Service Key")
GOSSEN METRAWATT GMBH

قانون اساسیصفحه 4
دانلود [ U1660 دیتاشیت ]



دیتاشیت توصیه

شماره قطعه شرح مفصل تولید کنندگان
U1660 LON-Add-On Component Meter Reading Module GOSSEN METRAWATT
GOSSEN METRAWATT
U1660G 16 Ampere Surface Mount Common Cathode Ultra Fast Recovery Rectifier Thinki Semiconductor
Thinki Semiconductor
U1660RG 16 Ampere Surface Mount Common Anode Ultra Fast Recovery Rectifier Thinki Semiconductor
Thinki Semiconductor

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2018   |   تماس با ما  |   جستجو