DataSheetWiki


V23086-R1851-A502 fiches techniques PDF

Tyco - PCB Single Relays

Numéro de référence V23086-R1851-A502
Description PCB Single Relays
Fabricant Tyco 
Logo Tyco 





1 Page

No Preview Available !





V23086-R1851-A502 fiche technique
Automotive Relays
PCB Single Relays
Micro Relay K (THT – THR)
n Small power relay
n Limiting continuous current 30A
n Low weight
n Low noise operation
n Wave (THT) and reflow (THR/pin-in-paste) solderable versions
Typical applications
Car alarm, door control, door lock, heated front/rear screen, immobilizer,
lamps front/rear/fog light, interior lights, seat control, sun roof, window
lifter, wiper control.
Contact Data
Typical applications
Contact arrangement
Rated voltage
Rated current
Limiting continuous current
23°C
85°C
Limiting making current
Limiting breaking current
Contact material
Min. recommended contact load
Initial voltage drop at 10A, typ./max.
Operate/release time
Electrical enduranc
cyclic temperature -40°C, +25°C, +85°C
form C contact (CO) at 14VDC
Resistive/inductive load
V23086-*1*01-A403
1 form C, 1 CO
12VDC
NO/NC
30/25A
30/25A
20/15A
40A1)
30A
motor reverse blocked,
25A, 0.77mH
>1x105 ops.
form A contact (NO) at 14VDC
resistive 20A
>3x105 ops.
Wiper load
V23086-*1*02-A803
1 form C, 1 CO
10VDC
NO/NC
30/25A
30/25A
20/15A
40A1)
30A
AgSnO2
1A at 5VDC3)
30/300mV
typ. 3/1.5ms4)
wiper,
25A make/5A break,
generator peak,
20A on NC,1mH
>1x106 ops.
Mechanical endurance
>5x106 ops.
086C/R1_fcw1b
Resistive/inductive load
V23086-*1*01-A402
1 form A, 1 NO
12VDC
30A
30A
20A
40A1)
30A
Lamp load5)
V23086-*1*51-A502
1 form A, 1 NO
12VDC
30A
30A
20A
100A2)
30A
resistive 20A
>3x105 ops.
lamp 100A inrush,
10A steady state
>1x105 ops.5)
Max. DC load breaking capacity
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages. For a load current duration of maximum
3s for a make/break ratio of 1:10.
2) Corresponds to the peak inrush current on initial actuation (cold filament).
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) Measured at nominal voltage without coil suppression unit. A low resistive suppression
device in parallel to the relay coil increases the release time and reducesthe lifetime
caused by increased erosion and/or higher risk of contact tack welding.
5) Be aware of using right polarity, see Terminal Assignment. Wrong polarity will reduce
endurance.
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
10-2013, Rev. 1013
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
http://www.Datasheet4U.com

PagesPages 5
Télécharger [ V23086-R1851-A502 ]


Fiche technique recommandé

No Description détaillée Fabricant
V23086-R1851-A502 PCB Single Relays Tyco
Tyco

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche