NS-YB05C-B- Type Measurement Display Controller
Operating Instructions
Contents
1. Main features and technical parameters
1.1 Main features
1.2 Technical parameters
2. Wiring and electrifying
3. Instrument panel definition
4. Parameter setting and instruction
4.1 How to enter the parameters setting state
4.2 First level parameter
4.3 Second level parameters
5. Function setting and instruction
5.1 Alarm Control
5.2 Zero clearing setting
5.3 Peak value setting
5.4 Unit switch
5.5 Holding and printing
6. Instrument calibration
Free Datasheet http://www.Datasheet4U.com

1 page




NS-YB05C-B pdf
Instrument current signal input (three legs): connecting current output type sensor yellow line
Resistance output sensors and instrument wiring diagram:
AC220V
DC24V
Chart 2.1.2 The view of NS-YB05C-A after inputting resistance
Instrument resistance signal input (6 legs): The resistance centretap connecting resistance
output sensor
The five and seven legs of the instrument: Respectively connecting other two wires of the
resistance output sensor
0~20mV output sensor and instrument wiring diagram
AC220V
DC24V
Chart 2. 1.3 The view of inputting NS-YB05C-A 4~20mV signal
Instrument feeding output +5V (15 legs): Connecting mV output sensor red line
Instrument feeding output GND (16 legs): Connecting mV output sensor green line
5
Free Datasheet http://www.Datasheet4U.com

5 Page





NS-YB05C-B arduino
4.2 The second level parameter
For display order and meaning, please see list 4.3.0
Display
symbol
Param
eters
Name
Parameters
Name
Numerical
value setting
range
Instruction
Factory
value
SL0 Input graduation
0
1
420mA input
05V or mV input
1
0 No decimal point
1
Decimal point in ten’s place
(display xxxxx)
SL1 Decimal point
2
Decimal point in hundred’s place
(display xxxxx)
0
Decimal point in thousand ’s
3 place (display xxxxx)
4
Decimal point in ten thousands’
place (display xxxxx)
0 No alarm
1 The first alarm is lower limit alarm
SL2
The first alarm
mode
2
The first alarm is upper limit alarm
0
3 The first alarm is intra-area alarm
4
The first alarm is external-area
alarm
0 No alarm
1
The second alarm is lower limit
alarm
SL3
The second alarm
mode
2
The second alarm is upper limit
alarm
0
3 The first alarm is intra-area alarm
4
The first alarm is external-area
alarm
0 No alarm
1
The third alarm is lower limit
alarm
SL2.
The third alarm
mode
2
The third alarm is upper limit 0
alarm
3 The first alarm is intra-area alarm
The first alarm is external-area
4 alarm
SL3. The fourth alarm
mode
0
No alarm
0
1 The fourth alarm is lower limit alarm
2 The fourth alarm is upper alarm
3 The first alarm is intra-area alarm
11
Free Datasheet http://www.Datasheet4U.com

11 Page







PáginasTotal 17 Páginas
PDF Descargar[ Datasheet NS-YB05C-B.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
NS-YB05C-BType Measurement Display Controller Operating InstructionsETC
ETC
NS-YB05C-B-IDigital IndicatorETC
ETC
NS-YB05C-B-VDigital IndicatorETC
ETC
NS-YB05C-DMeasurements show that the control deviceETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar