DataSheet.es    


PDF EPC11 Data sheet ( Hoja de datos )

Número de pieza EPC11
Descripción HEATING REGULATOR manual
Fabricantes ENERPIPE 
Logotipo ENERPIPE Logotipo



Hay una vista previa y un enlace de descarga de EPC11 (archivo pdf) en la parte inferior de esta página.


Total 18 Páginas

No Preview Available ! EPC11 Hoja de datos, Descripción, Manual

HEATING REGULATOR EPC11
End user manual
www.enerpipe.de
Free Datasheet http://www.datasheet-pdf.com/

1 page




EPC11 pdf
1 Safety notes
Danger of scalding:
Some parts of this system may reach temperatures
exceeding 55°C (for thresholds of burning, see EN 563).
Be sure to point out all possibly existingdangers
(such as touchable surfaces, high temperatures
of used water) to all persons operating this system.
Danger of freezing:
Make sure that the selector switch does not remain
in the MAINTENANCE position forlonger periods of time
during winter. The heating pipes may freeze up.
MAINTENANCE position: There is no antifreeze monitoring!
CAUTION:
To disconnect the unit from the mains,
use the all-polar switch on the part of the builder.
Only a qualified expert must open the unit.
The unit is completely maintenance-free.
5
Free Datasheet http://www.datasheet-pdf.com/

5 Page





EPC11 arduino
3.3 Domestic hot water tank
The warm-water boiler is used to prepare
and make available the necessary heated
water for usage.
Mode
This indicates the current operation mode of
the boiler.
MinChg
The boiler always carries out a minimum loading
Figurre 6: DHW tank menu
outside its loading time if the minimum temperature of the boiler has fallen below.
DisInf
The boiler carries out its weekly disinfection charge.
Upper temperature
This indicates the current upper boiler temperature. Moreover, you can set the „required
boiler temperature“ and the „minimum boiler temperature“ here.
Required boiler temperature ( defaul t 55°C)
The required boiler temperature indicates which temperature (measured on the upper
boiler sensor) should be selected to charge the boiler within a loading time or during
a minimum temperature charge, respectively.
Minimum boiler temperature (default 45°C)
The minimum temperature shows the lower limit for the charging status of the boiler
(measured on the upper boiler) and causes a subsequent charging, if the temperature
has fallen below.
Lower temperature
This indicates the current lower boiler temperature.
Loading times
This is to configure the loading times of the boiler.
3.4 Circulation
A circulation pump is used to immediately prepare
and make available the heated water in a building.
For this purpose, the heated water in the warm water
Figure 7: Circulation menu
boiler is continuously circulated through the water pipe. This is to prevent the water for usage from
cooling off in the pipe. If there is no circulation pump, only cold water would be available to the user
when turning on the tap.
Mode
This indicates, whether the circulation is in
operation or not.
Operation times
The fixes operation times for the circulation
pump can be set here.
Return temperature
This indicates the return temperature of the circulation to the warm-water boiler.
11
Free Datasheet http://www.datasheet-pdf.com/

11 Page







PáginasTotal 18 Páginas
PDF Descargar[ Datasheet EPC11.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
EPC1Configuration DevicesAltera Corporation
Altera Corporation
EPC10EPC CoresACME
ACME
EPC1001Enhancement Mode Power TransistorEPC
EPC
EPC1005Enhancement Mode Power TransistorEPC
EPC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar