Número de pieza | CLAA154WB03N | |
Descripción | Display Module | |
Fabricantes | CHUNGHWA PICTURE TUBES | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de CLAA154WB03N (archivo pdf) en la parte inferior de esta página. Total 27 Páginas | ||
No Preview Available ! Chunghwa Picture Tubes, Ltd.
Technical Specification
To : STUDIO
Date : 2008/07/22
TFT LCD
CLAA154WB03 N
ACCEPTED BY :
www.DataSheet.net/
APPROVED BY
黃奕凱
CHECKED BY
劉益群
PREPARED BY
申珮君
Prepared by : TFT-LCD Product Planning Management Division
CHUNGHWA PICTUER TUBES, LTD.
1127 Hopin Rd., Padeh, Taoyuan, Taiwan 334, R.O.C.
TEL: +886-3-3675151 FAX: +886-3-377-3003
Doc.No: CLAA154WB03 N-STUDIO-V1-2008/07/22
Issue Date: 2008/07/22
Datasheet pdf - http://www.DataSheet4U.co.kr/
1 page CPT
CHUNGHWA PICTURES TUBES, LTD.,
2. ABSOLUTE MAXIMUM RATINGS
The following are maximum value, which if exceeded, may cause faulty operation or damage to the unit.
ITEM
SYMBOL
MIN. MAX.
UNIT
REMARK
Power Supply Voltage for LCD
VCC
0 4.0
V
Lamp voltage
VL
630 900
Vrms
Lamp current
IL
2 6.5 mArms
*1). 2)
Lamp frequency
FL
40 80
kHz
Operation Temperature
Top 0 50 ℃ *3). 4). 5). 6)
Storage Temperature
Tstg
-25 65
℃
*3). 4). 5)
Delayed Discharge Time
TD
-- 1
sec
*7)
【Note】
*1) Product life-time relate to lamp current, please operate production follow statement at page 9 〝(b)back light〞.
*2) When lamp current over the definition of absolute max, product life-time will decay rapidly or operate
unusual.
*3) The relative temperature and humidity range are as below sketch, 90%RH Max. (Ta≦40℃)
*4) The maximum wet bulb temperature ≦39℃(Ta>40℃) and without dewing.
*5) If product in environment which over the definition of the relative temperature and humidity out of range too
long, it will affect visual of LCD.
*6) If you operate LCD in normal temperature range, the center surface of panel should be under 60℃.
*7) Delay discharge time test condition :Starting lamp voltage=1650Vrms. (please follow statement at page 9
〝 (b) back light〞
Before test TD, lamp should operate at least 1min, and lamp current should follow trpical lamp current
specification. To place panel at room temp. ( 25±2℃)below for 24hrs,nd then to measure TD with the same starting
lamp voltage in dark room.
www.DataSheet.net/
Relative Humidity (%RH)
90
(40,90)
Operating Range
80
60
Storage
(50,50.4)Range
40 (60,27.7)
20
5
-20
0 25 40 50 60
Temperature (°C)
CPT Confidential
5/27
CLAA154WB03 N-STUDIO-V1-20080722
Datasheet pdf - http://www.DataSheet4U.co.kr/
5 Page CPT
5. INTERFACE TIMING CHART
5.1LCD Input Signal Timing Chart
5.1.1 Horizontal Timing sequence
tCLK
CHUNGHWA PICTURES TUBES, LTD.,
DCLK
DATA
(R,G, B)
DENA
Invalid Data
First Data
123
tHB tHA
5.1.2 Vertical Timing sequence:
tH
tV
www.DataSheet.net/
Last Data
1279 1280 Invalid Data
LINE DATA
DENA
Invalid Data
1 23
tVB tVA
799 800 Invalid Data
CPT Confidential
11/27
CLAA154WB03 N-STUDIO-V1-20080722
Datasheet pdf - http://www.DataSheet4U.co.kr/
11 Page |
Páginas | Total 27 Páginas | |
PDF Descargar | [ Datasheet CLAA154WB03N.PDF ] |
Número de pieza | Descripción | Fabricantes |
CLAA154WB03-AN | TFT LCD | CHUNGHWA PICTURE TUBES |
CLAA154WB03A | Display Module | CHUNGHWA PICTURE TUBES |
CLAA154WB03A-D | TFT LCD | CHUNGHWA PICTURE TUBES |
CLAA154WB03AN | Display Module | CHUNGHWA PICTURE TUBES |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |