DataSheet.es    


PDF W9464G6JH Data sheet ( Hoja de datos )

Número de pieza W9464G6JH
Descripción 1M X 4 BANKS X 16 BITS DDR SDRAM
Fabricantes Winbond 
Logotipo Winbond Logotipo



Hay una vista previa y un enlace de descarga de W9464G6JH (archivo pdf) en la parte inferior de esta página.


Total 52 Páginas

No Preview Available ! W9464G6JH Hoja de datos, Descripción, Manual

www.DataSheet.co.kr
W9464G6JH
1M 4 BANKS 16 BITS DDR SDRAM
Table of Contents-
1. GENERAL DESCRIPTION ......................................................................................................... 4
2. FEATURES ................................................................................................................................. 4
3. KEY PARAMETERS ................................................................................................................... 5
4. PIN CONFIGURATION ............................................................................................................... 6
5. PIN DESCRIPTION..................................................................................................................... 7
6. BLOCK DIAGRAM ...................................................................................................................... 8
7. FUNCTIONAL DESCRIPTION.................................................................................................... 9
7.1 Power Up Sequence....................................................................................................... 9
7.2 Command Function ...................................................................................................... 10
7.2.1
Bank Activate Command ........................................................................... 10
7.2.2
Bank Precharge Command........................................................................ 10
7.2.3
Precharge All Command............................................................................ 10
7.2.4
Write Command ......................................................................................... 10
7.2.5
Write with Auto-precharge Command........................................................ 10
7.2.6
Read Command ......................................................................................... 10
7.2.7
Read with Auto-precharge Command ....................................................... 10
7.2.8
Mode Register Set Command.................................................................... 11
7.2.9
Extended Mode Register Set Command ................................................... 11
7.2.10 No-Operation Command............................................................................ 11
7.2.11 Burst Read Stop Command ....................................................................... 11
7.2.12 Device Deselect Command ....................................................................... 11
7.2.13 Auto Refresh Command ............................................................................ 11
7.2.14 Self Refresh Entry Command .................................................................... 12
7.2.15 Self Refresh Exit Command....................................................................... 12
7.2.16 Data Write Enable /Disable Command ...................................................... 12
7.3 Read Operation............................................................................................................. 12
7.4 Write Operation............................................................................................................. 13
7.5 Precharge ..................................................................................................................... 13
7.6 Burst Termination.......................................................................................................... 13
7.7 Refresh Operation......................................................................................................... 13
7.8 Power Down Mode ....................................................................................................... 14
7.9 Input Clock Frequency Change during Precharge Power Down Mode........................ 14
7.10 Mode Register Operation.............................................................................................. 14
Publication Release Date: Oct. 20, 2011
- 1 - Revision A02
Datasheet pdf - http://www.DataSheet4U.net/

1 page




W9464G6JH pdf
www.DataSheet.co.kr
W9464G6JH
3. KEY PARAMETERS
SYMBOL
DESCRIPTION
CL = 2
tCK Clock Cycle Time
CL = 2.5
CL = 3
tRAS
tRC
IDD0
IDD1
IDD2F
IDD2Q
IDD4R
IDD4W
IDD5
IDD6
CL = 4
Active to Precharge Command Period
Active to Ref/Active Command Period
Operating current
Operation Current (Single bank)
Precharge floating standby current
Precharge quiet standby current
Burst Operation Current
Burst Operation Current
Auto Refresh Burst current
Self-Refresh Current
MIN/MAX.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Min.
Max.
Max.
Max.
Max.
Max.
Max.
Max.
Max.
-4
-
-
-
-
4 nS
10 nS
4 nS
10 nS
40 nS
55 nS
50 mA
60 mA
25 mA
25 mA
110 mA
105 mA
60 mA
2 mA
-5/-5I
7.5 nS
10 nS
6 nS
10 nS
5 nS
10 nS
-
-
40 nS
55 nS
45 mA
55 mA
25 mA
25 mA
100 mA
95 mA
60 mA
2 mA
-5-
Publication Release Date: Oct. 20, 2011
Revision A02
Datasheet pdf - http://www.DataSheet4U.net/

5 Page





W9464G6JH arduino
www.DataSheet.co.kr
W9464G6JH
1. READA tRAS (min) (BL/2) x tCK
Internal precharge operation begins after BL/2 cycle from Read with Auto-precharge command.
2. tRCD(min) READA < tRAS(min) (BL/2) x tCK
Data can be read with shortest latency, but the internal Precharge operation does not begin until
after tRAS (min) has completed.
This command must not be interrupted by any other command.
7.2.8 Mode Register Set Command
( RAS = “L”, CAS = “L”, WE = “L”, BA0 = “L”, BA1 = “L”, A0 to A11 = Register Data)
The Mode Register Set command programs the values of CAS Latency, Addressing Mode, Burst
Length and DLL reset in the Mode Register. The default values in the Mode Register after power-
up are undefined, therefore this command must be issued during the power-up sequence. Also,
this command can be issued while all banks are in the idle state. Refer to the table for specific
codes.
7.2.9 Extended Mode Register Set Command
( RAS = “L”, CAS = “L”, WE = “L”, BA0 = “H”, BA1 = “L”, A0 to A11 = Register data)
The Extended Mode Register Set command can be implemented as needed for function
extensions to the standard (SDR-SDRAM). Currently the only available mode in EMRS is DLL
enable/disable, decoded by A0. The default value of the extended mode register is not defined;
therefore this command must be issued during the power-up sequence for enabling DLL. Refer to
the table for specific codes.
7.2.10 No-Operation Command
( RAS = “H”, CAS = “H”, WE = “H”)
The No-Operation command simply performs no operation (same command as Device Deselect).
7.2.11 Burst Read Stop Command
( RAS = “H”, CAS = “H”, WE = “L”)
The Burst stop command is used to stop the burst operation. This command is only valid during a
Burst Read operation.
7.2.12 Device Deselect Command
( CS = “H”)
The Device Deselect command disables the command decoder so that the RAS , CAS ,
WE and Address inputs are ignored. This command is similar to the No-Operation command.
7.2.13 Auto Refresh Command
( RAS = “L”, CAS = “L”, WE = “H”, CKE = “H”, BA0, BA1, A0 to A11 = Don’t Care)
AUTO REFRESH is used during normal operation of the DDR SDRAM and is analogous to CAS
BEFORERAS (CBR) refresh in previous DRAM types. This command is non persistent, so it
must be issued each time a refresh is required.
The refresh addressing is generated by the internal refresh controller. This makes the address
bits ”Don’t Care” during an AUTO REFRESH command. The DDR SDRAM requires AUTO
- 11 -
Publication Release Date: Oct. 20, 2011
Revision A02
Datasheet pdf - http://www.DataSheet4U.net/

11 Page







PáginasTotal 52 Páginas
PDF Descargar[ Datasheet W9464G6JH.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
W9464G6JH1M X 4 BANKS X 16 BITS DDR SDRAMWinbond
Winbond

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,