DataSheetWiki


TFS125L fiches techniques PDF

Vectron International - VI TELEFILTER

Numéro de référence TFS125L
Description VI TELEFILTER
Fabricant Vectron International 
Logo Vectron International 





1 Page

No Preview Available !





TFS125L fiche technique
Filename: tfs 125l.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23 °C
0 dBm
650 || -14,5 pF
750 || -12,8 pF
TFS 125L
15.10.2004
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 125L is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 125 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae 5,7 dB
min. 7 dB
Nominal frequency
fN -
125 MHz
Passband
Pass band ripple
fN
± 200
kHz
-
max.
1 dB
Relative attenuation
fN
fN ±
fN ±
fN ±
fN ±
fN ±
fN ±
fN -
fN +
0,6
1,2
1,8
3,4
6,5
9,5
115
17
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Group delay
… fN
… fN
… fN
… fN
… fN
… fN
… fN
… fN
… fN
±
±
±
±
±
±
±
-
+
arel
200 kHz
1,2
1,8
3,4
6,5
9,5
17
17
325
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
at fN
0,6 dB
11 dB
30 dB
35 dB
45 dB
55 dB
60 dB
75 dB
75 dB
1,1 µs
max.
min.
min.
min.
min.
min.
min.
min.
min.
max.
min.
1 dB
8 dB
20 dB
25 dB
34 dB
40 dB
43 dB
55 dB
55 dB
1,7 µs
0,7 µs
Group delay ripple within PB
60 ns
max. 120 ns
VSWR
1,5
max.
2,3
Input power level
-
max.
10 dBm
Operating temperature range
OTR
-
- 10 °C ... + 85 °C
Storage temperature range
- - 40 °C ... + 85°C
Frequency inversion temperature
37 °C
-
Temperature coefficient of frequency
TCf **
-0,04 ppm/K2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fc(Hz) = Tcf(ppm/K²) x (To - TA) ² x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
www.DataSheet4U.net

PagesPages 5
Télécharger [ TFS125L ]


Fiche technique recommandé

No Description détaillée Fabricant
TFS125A VI TELEFILTER Vectron International
Vectron International
TFS125B VI TELEFILTER Vectron International
Vectron International
TFS125C VI TELEFILTER Vectron International
Vectron International
TFS125D VI TELEFILTER Vectron International