Development Specification
TFS 770
13.10.2003
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23 °C
0 dBm
50
50
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 770 MHz without any tolerance or limit.
The values of absolute attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
Nominal frequency
ae -
fN -
max.
2,5
770
dB
MHz
Passband
Pass band ripple
PB -
-
fN ±
max.
6 MHz
0,7 dB
Absolute attenuation
aabs
0 MHz ...
707 MHz ...
723 MHz ...
739 MHz ...
800 MHz ...
813 MHz ...
868 MHz ...
998 MHz ...
707
723
739
743
813
868
998
1910
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
-
-
-
-
-
-
-
-
-
T.B.D
ppm/K
min. 45 dB
min. 40 dB
min. 35 dB
min. 25 dB
min. 15 dB
min. 30 dB
min. 50 dB
min. 30 dB
- 30 °C ... + 85 °C
- 40 °C ... + 85 °C
-
Input power level
-
max.
15 dBm
VSWR
PB -
max.
2:1
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
www.DataSheet4U.net

1 page




TFS770 pdf
File name : TFS770.doc
VI TELEFILTER
version 1.1
Development Specification
History
Version Reason of Changes
1.0 - Generation of development specification
1.1 - Changes of remark in characteristics
TFS 770
13.10.2003
5/5
Name
Roizengaft
Roizengaft
Date
8.10.2003
13.10.2003
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet TFS770.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
TFS770VI TELEFILTERTele Filter GmbH
Tele Filter GmbH
TFS770CVI TELEFILTERTele Filter GmbH
Tele Filter GmbH
TFS770FVI TELEFILTERTele Filter GmbH
Tele Filter GmbH
TFS77AVI TELEFILTERTele Filter GmbH
Tele Filter GmbH

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar