DataSheetWiki


440LD40 fiches techniques PDF

Vishay Siliconix - AC Line Rated Disc Capacitors

Numéro de référence 440LD40
Description AC Line Rated Disc Capacitors
Fabricant Vishay Siliconix 
Logo Vishay Siliconix 





1 Page

No Preview Available !





440LD40 fiche technique
440L, 30LV, 30LVS, 25Y, 125L, 20VL Series
Vishay Cera-Mite
AC Line Rated Disc Capacitors
X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE,
LINE-BY-PASS, ANTENNA COUPLING
Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors specically designed and tested
for use on 125 Volt through 600 Volt AC power sources. Certied to meet demanding X & Y type worldwide
safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass
ltering applications. Vishay Cera-Mite offers the most
complete selection in the industrysix product families
exactly tailored to your needs.
AC LINE RATED CERAMIC CAPACITOR SPECIFICATIONS
Worldwide Safety Agency Recognition
- Underwriters Laboratories - UL1414 & UL1283
- Canadian Standards Association - CSA 22.2 No. 1 & No. 8
- European EN132400 to IEC 384-14 Second Edition
Required In AC Power Supply and Filter Applications
Six Families Tailored To Specific Industry Requirements
Complete Range of Capacitance Values
PERFORMANCE DATA / SERIES: 440L 30LV 30LVS 25Y 125L 20VL
Application Voltage Range
(Vrms 50/60 Hz) (Note 1)
250/500 300/400 250/400 250/400 250 250
Dielectric Strength
(Vrms 50/60 HZ for 1 minute)
4000 2500 2500 2500 2000 1250
Dissipation Factor (Maximum)
2%
Insulation Resistance (Minimum)
1000 F
Mechanical Data
Service Temperature 125°C Maximum;
Coating Material per UL94V0
Temperature Characteristics
Y5U Y5U Y5U Y5S Y5V Y5V
See Part Number Detail for Temperature Characteristics
SAFETY AGENCY RECOGNITION AND EMI/RFI FILTERING SUBCLASS
Series / Recognition / Voltage
440L
30LV
30LVS
25Y
125L
20VL
Underwriters Laboratories Inc.: (Note 2)
UL 1414 Across-The-Line
Across-The-Line Across-The-Line
— ——
UL 1414 Antenna Coupling
Antenna-Coupling Antenna-Coupling
— ——
UL 1414 Line-By-Pass
Line-By-Pass Line-By-Pass Line-By-Pass Line-By-Pass Line-By-Pass
UL 1414 Rated Voltage
250 VAC
250 VAC
250 VAC
250 VAC
250 VAC
Electromagnetic Interference Filters
EMI Filters
EMI Filters
EMI Filters
EMI Filters
EMI Filters
UL1283 Rated Voltage
600 VAC
250 VAC
250 VAC
250 VAC
250 VAC
Canadian Standards Association:
CSA 22.2 No.1 Across-The-Line
Across-The-Line Across-The-Line
— ——
CSA 22.2 No.1 Isolation
Isolation
Isolation
Isolation
Isolation
Isolation
CSA 22.2 No. 1 Rated Voltage
250 VAC
250 VAC
250 VAC
250 VAC
125/250 VAC
CSA 22.2 No. 8 Line-to-Ground Capacitors
Line-To-Ground Line-To-Ground Line-To-Ground Line-To-Ground
For Use in Certified EMI Filters
Certified EMI Filters Certified EMI Filters Certified EMI Filters Certified EMI Filters
CSA 22.2 No. 8 Rated Voltage
400 VAC
400 VAC
400 VAC
250 VAC
European CENELEC Electronic Components Committee (CECC) EN 132 400 to Publication IEC 384-14 Table II, Edition 2:
IEC 384 -14 Second Edition Subclass Y: (Note 3)
Y1
Y2
Y2
Y2 Y4
Subclass Y Voltage (Vrms 50-60 Hz)
500 VAC
300 VAC
250 VAC
250 VAC
125 VAC
Type of Insulation Bridged
Double or
Basic or
Basic or
Basic or
Basic or
Reinforced Supplementary Supplementary Supplementary Supplementary
Peak Impulse Voltage Before Endurance Test
8 kV
5 kV
5 kV
5 kV 2.5 kV
IEC 384-14 Second Edition Subclass X: (Note 4)
X1
X1
X1
X1 X1 X2
Subclass X Voltage (Vrms 50-60 Hz)
400 VAC
400 VAC
400 VAC
400 VAC
400 VAC
400 VAC
Peak Impulse Voltage in Service
2.5 to 4.0 kV
2.5 to 4.0 kV
2.5 to 4.0 kV
2.5 to 4.0 kV 2.5 to 4.0 kV
To 2.5 kV
Application
High Pulse
High Pulse
High Pulse
High Pulse
High Pulse Gen. Purpose
Damp Heat, Steady State Recognition
Code HKF - 25°C/ + 125°C/21 days
Note 1
Voltage Ratings: All ratings are manufacturers
rating.
Part markings are governed by agency
rules and customer requirements.
Parts are marked 250 VAC unless otherwise
requested.
Note 2
UL1414 Across-The-Line, Antenna Coupling, and
wwwL.Dinea-tBayS-PhaesestC4aUp.accoitomrs:
Across-The-LineA capacitor connected
either across a supply circuit or between
one side of a supply circuit and a conductive
part that may be connected to earth ground.
Antenna-CouplingA capacitor connected
from an antenna terminal to circuits within an
appliance.
Line-By-PassA capacitor connected between
one side of a supply circuit and an accessible
conductive part.
Note 3
IEC 384-14 Subclass Y Capacitors:
A capacitor of a type suitable for use in situations
where failure of the capacitor could lead to
danger of electric shock.
Class Y capacitors are divided into sub- classes
based on type of insulation bridged and voltage
ranges.
For definitions of basic, supplementary,
double and reinforced insulation, see IEC
Publication 536.
Subclass Y capacitors may be used in
applications which require a Subclass
X rating.
Note 4
IEC 384-14 Subclass X Capacitors:
A capacitor of a type suitable for use
in situations where failure of the capacitor
would not lead to danger of electric
shock.
Class X capacitors are divided into subclasses
according to the peak impulse test voltage
superimposed on the main voltage
Note 5
AC Leakage Current:
For all Series (except 125L) - AC Leakage
Current (mA) specified at 250 Vrms, 60 Hz.
• For 125L Series - AC Leakage Current
(mA) specified at 125 Vrms, 60Hz.
Note 6
Alternate Lead Spacings of 7.5mm and 10mm
are available bulk or tape & reel.
European Required Minimum Lead Clearance
(Prevents Use of Inside Crimp) .315" (8mm) on
440L Series; 0.118" (3mm) on all other series.
www.vishay.com
20
Document Number: 23092
Revision 14-May-02

PagesPages 3
Télécharger [ 440LD40 ]


Fiche technique recommandé

No Description détaillée Fabricant
440LD40 AC Line Rated Disc Capacitors Vishay Siliconix
Vishay Siliconix
440LD47 AC Line Rated Disc Capacitors Vishay Siliconix
Vishay Siliconix

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche