DataSheetWiki


FGDS-2A-50V fiches techniques PDF

Gaia Converter - EMI Filters

Numéro de référence FGDS-2A-50V
Description EMI Filters
Fabricant Gaia Converter 
Logo Gaia Converter 





1 Page

No Preview Available !





FGDS-2A-50V fiche technique
MIL-STD-461 EMI INPUT FILTER
FGDS-2A-50V up to 2A CURRENT
HHi-iR-eRlel
GGrardaede
www.DataSheet4U.com
2A EMI Filter Module
9 to 50 VDC Input Range
MIL-STD-461C/D/E/F Compliant
• To comply with MIL-STD-461D/E/F power leads :
• CE 102 : Emission requirement over 10KHz to 10MHz
• CS 101 : Susceptibility requirement over 30Hz to 150KHz
• CS 114 : Susceptibility requirement over 10KHz to 400MHz
• CS 115 : Susceptibility requirement for spikes
1-General
• To comply with MIL-STD-461C power leads :
• CE 03 : Emission requirement over 15KHz to 50MHz
• CS 01 : Susceptibility requirement over 30Hz to 50KHz
• CS 02 : Susceptibility requirement over 15KHz to 400MHz
• CS 06 : Susceptibility requirement for spikes
• To comply with DO-160C/D/E/F power lines :
• Conducted emission requirement over 15KHz to 30MHz
• Conducted susceptibility requirement over 10KHz to 400MHz
• Susceptibility requirement for induced transients
The GAIA Converter filter module FGDS-2A-50V
provides a state-of-the-art product to fulfill
Electromagnetic Interferences (EMI) requirements
for Aerospace/Defence applications.
The FGDS-2A-50V complies with major standards
including :
the US MIL-STD-461 rev C, D, E and rev F
the international DO-160 rev C, D, E and rev F
In particular, the filter module is compliant with
the following requirements of MIL-STD-461 and
DO-160 standards :
• Temperature range :
• operating temperature : -40°C/+105°C case
• storage temperature : -55°C/+125°C
• RoHS process
MIL-STD-461C Part 2. & 3. requirements :
Conducted Emission (CE)
CE03, power leads, emission over
15KHz to 50MHz, narrowband, Class A1
CE03, power leads, emission over
15KHz, broadband, Class A1 curve#
1&2
Conducted Susceptibility (CS)
CS01, power leads, frequency over 30Hz
to 50KHz, class A1, consult factory
for criteria
CS02, power leads, frequency 15KHz
to 400MHz, class A1
CS06, power leads, spike #1
2-Product Selection
MIL-STD-461D/E/F Part 2. & 3. requirements :
Conducted Emission (CE)
CE102, power leads, emission over
10KHz to 10MHz, basic curve
Conducted Susceptibility (CS)
CS101, power leads, frequency 30Hz
to 150KHz, curve #1
CS114, bulk cable injection, frequency
10KHz to 400MHz
CS115, spikes, bulk cable injection,
calibrated spike
CS116, damped sinusoidal transient
DO-160-C/D/E/F requirements :
Conducted Emission (CE)
Section 21 power lines, emission over
15KHz to 30MHz, category B, AZ & LMH
Conducted Susceptibility (CS)
Section 20 power lines, frequency 10KHz
to 400MHz
6
In addition, this filter withstands in a transparent
state without dammage the transient and spike
requirements of :
MIL-STD-704A with 80V/100ms & 600V/10µs
MIL-STD-1275B with 100V/50ms & 250V/70µs
The FGDS-2A-50V is suitable for all GAIA
Converter DC/DC converters and architecture
from 4W up to 50W output power
up to 2A output current
up to 50V permanent input voltage.
FGDS-2A-50V/ option
Options :
/T : option for -55°C start up operating temperature
/S : option for screening and serialization
REDEFINING THE SOURCE OF POWER
© Gaia Converter FC05-050.01/10 Revision D
For locations, phone, fax, E-Mail see back cover

PagesPages 10
Télécharger [ FGDS-2A-50V ]


Fiche technique recommandé

No Description détaillée Fabricant
FGDS-2A-50V EMI Filters Gaia Converter
Gaia Converter

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche