DataSheet.es    


PDF C2260 Data sheet ( Hoja de datos )

Número de pieza C2260
Descripción TCXO
Fabricantes Vectron International 
Logotipo Vectron International Logotipo



Hay una vista previa y un enlace de descarga de C2260 (archivo pdf) en la parte inferior de esta página.


Total 5 Páginas

No Preview Available ! C2260 Hoja de datos, Descripción, Manual

C2260
TCXO
Typical Applications
PCS Base Stations
Land Mobile Radio
Cellular Telephony
Radio in the Local Loop
Features
EFC Standard
Low Profile
Small Size
100 % RoHS compliant
Frequency range
6.4 MHz – 52 MHz
Standard frequencies
10; 12.8; 19.44; 20MHz, 20.48MHz
Frequency stabilities1
Parameter
vs. operating temperature range
(Referenced to +25°C)
www.DPaartaamSheeteert4U.com
Initial tolerance
vs. supply voltage change
vs. load change
vs aging /1. Year
Min
Typ
Max.
Units
Operating temp
range
Ordering Code5
-2.5
+2.5 ppm
-20 … +70°C
D256
-1.0
+1.0 ppm
-20 … +70°C
D106
-1.0
+1.0 ppm
0 … +50°C
B106
-0.5
+0.5 ppm
0 … +50°C
B507
Min
Typ
Max.
Units
Condition
- 2.5
+2.5 ppm
at time of shipment, nominal EFC
- 0.5
- 0.2
+0.5
+0.2
ppm
ppm
VS ± 5%
Load ± 10%
- 1.0
+1.0 ppm
Frequency stabilities1 [ Stratum 3 TCXO] < 32MHz
Parameter
Min Typ Max.
vs. operating temperature range
(Referenced to +25°C)
-0.8
-0.28
-0.28
-0.80
-0.28
-0.28
+0.8
+0.28
+0.28
+0.80
+0.28
-0.28
Units
ppm
ppm
ppm
ppm
ppm
ppm
Operating temp
range
-20 … +70°C
0 … +50°C
-20 … +70°C
-40 … +85°C
-30 … +85°C
-40 … +85°C
Ordering Code5
D807
B287*
D287*
F807
G287
F287
Parameter
Initial tolerance
vs. supply voltage change
vs. load change
vs aging /15 Years
overall tolerance
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Current consumption
Min
Typ
Max.
Units
Condition
- 1.0
+1.0 ppm
at time of shipment, nominal EFC
- 0.2
- 0.1
+0.2
+0.1
ppm
ppm
VS ± 5%
Load ± 10%
- 2.5
+2.5 ppm
-4.6 -4.6 ppm
Note
* Stratum 3 per GR-1244-CORE:
<±4.6 ppm for all causes and 20 years
aging,Holdover: <±0.37 ppm over 24 hours
(Code: D287 & B287)
Min
Typ
Max.
Units
3.135
3.3
3.465
VDC
6 mA
Condition
Ordering Code5
SV033
steady state @ +25°C
RF output
Parameter
Signal [Standard]
Load R
|| C
Output power
Min
Typ
Max.
Units
Condition
clipped Sinewave
> 12.288MHz
9 10 11 kΩ
Ordering Code5
RFC
9 10 11 pF
0.7 Vpp
@ 10k||10pF
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2005-12-15 · page 1 of 5
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju
Road, WaiGaoQiao Free Trade Zone,
Pudong, Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax

1 page




C2260 pdf
C2260
Recommended Reflow Profile
TCXO
www.DataSheet4U.com
Profile Feature
Pb-Free Assembly
/Sn-Pb Assembly
Profile Feature
Pb-Free Assembly
/Sn-Pb Assembly
Average ramp-up rate (TL to Tp)
3°C/second max.
Time 25°C to Peak Temperature 8 minutes max.
Preheat -Temperature Min Tsmin)
-Temperature Min Tsmax)
-Time (min to max) (ts)
150°c
200°c
60-180 seconds
Time maintainted above
- Temperature (TL)
- Time (tL)
217°C
60-150 seconds
Tsmax to TL - Ramp-up Rate
Time maintainted above - Temperature (TL)
- Time (tL)
Peak Temperature (Tp)
3°C/second max.
217°C
60-150 seconds
max 260°C
Time within 5°C of actual
Peak Temperature (tp)
Ramp-down Rate
20-40 seconds
6°C/second max.
Note: All temperatures refer to topside of the package, measured on the package body surface.
How to Order this Product:
Step 1 Use this worksheet to forward the following information to your factory representative:
Model
C2260
Example: C2260
Stability Code
D106
Supply Voltage Code RF Output Code
SV033
RFC
Package Code
A1
Frequency
12.8MHz
Step 2 The factory representative will then respond with a Vectron Model Number in the following Configuration:
Model
C2260
Typical P/N = C2260A1-0001
Package Code
[Customer Specified Package Code]
Dash
-
Dash Number
[Factory Generated 4 digit number]
Notes:
1
2
3
4
5
Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies.
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control
voltage, load, temperature (25°C)
Phase noise degrades with increasing output frequency.
Subject to technical modification.
Contact factory for availability.
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2005-12-15 · page 5 of 5
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju
Road, WaiGaoQiao Free Trade Zone,
Pudong, Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet C2260.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
C2260TCXOVectron International
Vectron International
C2263NPN Transistor - 2SC2263Panasonic
Panasonic

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar