H HiTRON
UNIVERSAL INPUT AC-DC PCB OPEN FRAME
SINGLE OUTPUT 10-25 WATTS INTERNAL SWITCHING
POWER SUPPLIES HVI20 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Range typ. 90-264Vac.
Rating 100-240Vac.
Input Connector: IEC320-3P DT7.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 25A @ 230Vac.
Input Current: Typ. 0.47A @ 115Vac, 0.21A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
www.DEaMtaSI:heMete4eUt.CcoImSPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 10.0mS @ 115Vac, 40.0mS@ 230Vac.
Earth Leakage: Less than 0.7mA @ 230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 20 Watts.
Output Connector: Molex 5273.
Line Regulation: Typ. 0.1%.
Load Regulation: Typ. ±1.0%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1 only.
Adjustability: Not adjustable.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 70-75%
Switching Frequency: 40K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Output voltage returns in
less than 3mS following
a 25% load change.
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
Operating Temperature: 0 to +50 °C.
Storage Temperature: -20 to +85 °C.
Temperature Coefficient: Typ. 0.04%/ °C.
Cooling: Free air convection.
Construction: PCB open frame format.
Power Density: 1.79Watts / Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
-9-

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet HVI20.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HVI20UNIVERSAL INPUT AC-DC PCB OPEN FRAME SINGLE OUTPUT 10-25 WATTS INTERNAL SWITCHING POWER SUPPLIESHITRON ELECTRONICS
HITRON ELECTRONICS

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar