DataSheetWiki


NTQ123 fiches techniques PDF

Emerson - AC-DC / 86W - 135W

Numéro de référence NTQ123
Description AC-DC / 86W - 135W
Fabricant Emerson 
Logo Emerson 





1 Page

No Preview Available !





NTQ123 fiche technique
70-120 Watts
NTQ123 Series
Total Power: 70-120 Watts
Input Voltage: 85-264 VAC
# of Outputs: Quad
Special Features
• Active power factor correction
• EN61000-3-2 compliance
• Remote sense on outputs one and two
• Power fail and remote inhibit
• Single wire current sharing on outputs one
and two
• Adjustable main outputs
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
Environmental
Operating temperature: 0° to 50°C ambient; derate
each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >1 million hours at full load
and 25°C ambient conditions
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground leakage
current
Output
Maximum power
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Logic Control
Power failure
Remote inhibit
Remote sense
85-264 VAC
47-63 Hz
38 A max., cold start @ 25°C
65% typical at full load
FCC Class B conducted and radiated,
CISPR 22 Class B conducted and
radiated, EN55022 Class B conducted
and radiated, VDE 0878 PT3 Class B
conducted and radiated.
0.99 typical
<1 mA @ 50/60 Hz, 264 VAC input
70 W convection,
120 W with 30 CFM forced air
±5% minimum on outputs one and two
20 ms @ 120 W load, 120 VAC input
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
3.3 V and 5 V output: 20% to 35%
above nominal output
TTL logic signal goes high 100-500
msec after 5 V output; it goes low at
least 4 msec before loss of regulation
Requires an external TTL Signal to
inhibit outputs
Compensates for 0.5 V lead drop
minimum, will operate without remote
sense connected. Reverse connection
protection.
VDE
UL
CSA
NEMKO
BABT
CB
CE
Safety
0805/EN60950 (IEC950)
21310-3336-0004
UL1950
E186249
CSA 22.2-234 Level 3 LR109492C
EN 60950/EMKO-TUE P98100870
(74-sec) 203
EN60950/EN41003
608497
Certificate and report
5009
Mark (LVD)
Technical Support: (888) 41-ASTEC or (407) 241-2752
106
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 10.19.04

PagesPages 2
Télécharger [ NTQ123 ]


Fiche technique recommandé

No Description détaillée Fabricant
NTQ123 AC-DC / 86W - 135W Emerson
Emerson
NTQ123-DC AC-DC / 86W - 135W Emerson
Emerson

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche