DataSheetWiki


NLP250N-99S12J fiches techniques PDF

Emerson - AC-DC / 136W - 260W Medical

Numéro de référence NLP250N-99S12J
Description AC-DC / 136W - 260W Medical
Fabricant Emerson 
Logo Emerson 





1 Page

No Preview Available !





NLP250N-99S12J fiche technique
Embedded Power for
Business-Critical Continuity
NLP250 Medical
Series
Single Output
Rev.10.1.09_181
NLP250 Medical Series
 of 4
Total Power: 250 W
Input Voltage: 85 - 264 VAC
# of Outputs: Single
Special Features
• Medical safeties
• Active PFC and
EN61000-3-2 compliant
• 250 W on main channel with
forced air
• Low profile fits 1U applications
• U-Channel for maximum
thermal performance
• Optional cover (CJ suffix)
• 5 V standby output
• 12 V fan output
• Integrated control and
monitoring features
• Overcurrent, overvoltage and
overtemperature protection
• Compliance to EN55022-B
conducted noise standard
• Dual AC fuses
• RoHS compliant
• 2 year warranty
Safety
• VDE0750/EN60950
IEC950/IEC60601-1
File No. 1177400-3336-0759
• UL60601-1
File No. E186249
• Certificate No. 40014041
• CB Ref DE1-36628
Electrical Specifications
Input
Input voltage range:
Input frequency range:
Input surge current:
Safety ground leakage current:
Input current:
Input fuse:
Output
Maximum power:
Adjustment range:
Total regulation:
(line and load)
Turn-on delay:
Transient response:
Universal input
264 Vac (cold start)
264 Vac, 50 Hz
120 Vac @ 250 W
230 Vac @ 250 W
UL/IEC127
200 LFM forced air
250 LFM with cover
Main output
Main output
Auxiliary outputs
@ 120 Vac Input
Main output
50 - 100%
Step at 0.5 A/µs
85 - 264 Vac
47 - 63 Hz
40 A max.
150 µA
2.78 A rms
1.36 A rms
T6.4 AH, 250 Vac In live and
neutral
250 watts
± 5%
± 2.0%
± 5.0%
2.0 s max.
5.0% or 250 mV
max. dev., 1 ms max
recovery to 1%
Temperature coefficient:
Overvoltage protection:
Short circuit protection:
Minimum output current:
Auxiliary outputs:
(See Note 8, page 3)
Main output
Cyclic operation
Singles
5 Vsb
12 V (fan)
±0.02%/°C
115%, ± 5%
Continuous
0A
5 V @ 1.0 A
12 V @ 0.3A
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated

PagesPages 4
Télécharger [ NLP250N-99S12J ]


Fiche technique recommandé

No Description détaillée Fabricant
NLP250N-99S12CJ AC-DC / 136W - 260W Medical Emerson
Emerson
NLP250N-99S12J AC-DC / 136W - 260W Medical Emerson
Emerson

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche