DataSheetWiki


TFS110T fiches techniques PDF

Vectron International - Filter specification

Numéro de référence TFS110T
Description Filter specification
Fabricant Vectron International 
Logo Vectron International 





1 Page

No Preview Available !





TFS110T fiche technique
Filename: tfs110t.doc
VI TELEFILTER
Filter specification
Version 2.3
TFS 110 T
13.03.2002
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level :
0 dBm
Terminating impedances at fc *: for input:
for output:
930 Ω || - 13,5 pF
940 Ω || - 15,2 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 110 T is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies
at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 110.592 MHz without tolerance. The given
values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance
for the centre frequency fc.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae = amin
7,5 dB
max. 14,0 dB
Nominal frequency
Centre frequency
fN
fc
Relative attenuation arel
fN ... fN ±
fN ± 0,6 MHz ... fN ±
0,3
5
MHz
MHz
Group delay ripple in PB
-
110,592 MHz
-
38 dB
380 ns
110,592 MHz
max. 3
min. 30
max. 800
dB
dB
nsec
Temperature coefficient
Operating temperature range
Storage temperature range
0,032 ppm/K2
- 40 °C ... + 85
- 40 °C ... + 85
°C
°C
Input power
max. 10
dBm
www.DataSheet4U.com
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked / approved:
Construction and Pin Connection
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information

PagesPages 5
Télécharger [ TFS110T ]


Fiche technique recommandé

No Description détaillée Fabricant
TFS110D Filter Specification Vectron International
Vectron International
TFS110K1 Filter ETC
ETC
TFS110K2 TELEFILTER Filter specification ETC
ETC
TFS110P Filter specification Vectron International
Vectron International

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche