|
|
Número de pieza | SDS120 | |
Descripción | AC-DC Power Supplies | |
Fabricantes | XP Power Limited | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de SDS120 (archivo pdf) en la parte inferior de esta página. Total 2 Páginas | ||
No Preview Available ! 120 Watts
SDS120www.DataSheet4U.com Series
xppower.com
• Single, Dual & Triple Outputs
• Convection-cooled
• 3” x 5” Footprint
• High Efficiency to 85%
• Open Frame, U-Channel & Covered Versions
• Low Temperature Option
• Optional Power Fail Detect Signal
Specification
Input
Input Voltage
• 90-264 VAC (120-370 VDC)
Input Frequency
• 47-63 Hz
Input Current
• 1.7 A at 115 VAC
1.0 A at 230 VAC
Inrush Current
• <30 A at 115 VAC
<55 A at 230 VAC
Power Factor
• 0.97 typical
Earth Leakage Current • <0.30 mA at 115 VAC
<0.75 mA at 230 VAC
Input Protection
• 3.15 A on board fuse
Output
Output Voltage
• See table
Output Voltage Trim • ±5% output 1 only (3.3 V variant ±10%)
Initial Set Accuracy
• Single output models: ±1%
Multi-output models: ±5%
Minimum Load
• No minimum load required for single
output models. For multi-output models
see table.
Start Up Delay
• 2 s max
Start Up Rise Time
• 2 ms
Hold Up Time
• >16 ms
Line Regulation
• 1% maximum, ±0.5% typical
Load Regulation
• 5% maximum, ±3.0% typical
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 1% pk-pk typical, 20 MHz BW
Overvoltage Protection • 112-132% V1 only, recycle input to reset
Overload Protection
• All outputs: 110-150% with auto recovery
(primary power limit)
Short Circuit Protection • Trip & restart (Hiccup mode),
auto recovery
Temperature
Coefficient
• 0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 80% typical, 85% max,
230 VAC 100% load
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• PFC 100 kHz, PWM 67 kHz
• 4.87 W/In3
• Power Fail Detect = TTL active low,
combined AC and DC OK signal (option)
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +50 °C to 50% load at +70 °C,
low temperature option ‘-L’ -40 °C
Cooling
• Convection-cooled
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, CISPR22 and FCC, part 15
level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, >95% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA60950-1 per cUL, CE Mark LVD
1 page |
Páginas | Total 2 Páginas | |
PDF Descargar | [ Datasheet SDS120.PDF ] |
Número de pieza | Descripción | Fabricantes |
SDS120 | AC-DC Power Supplies | XP Power Limited |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |