No Preview Available ! LANK Hoja de datos, Descripción, Manual

LANK 10W Series
2:1 Wide Input Range
Single and Dual Output
10 Watt DC/DC Converter
FEATURES
I/O Isolation 1500VDC
MTBF > 1,000,000 Hours
Industry Standard Pinout
High Efficiency up to 88%
CSA1950 Safety Approval
2:1 Wide Input Voltage Range
Complies with EN55022 Class A
www.DataSShheeot4rUt .Ccoimrcuit and Over Voltage Protection
SPECIFICATIONS: LANK 10W Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min Nom Max Unit
INPUT (Vin)
12V input models
9 12 18 VDC
Input Voltage Range
24V input models
18 24 36 VDC
48V input models
36 48 75 VDC
12V input models
7 8 9 VDC
Start Voltage
24V input models
14 16 18 VDC
48V input models
30 33 36 VDC
12V input models
8.5 VDC
Under Voltage Shutdown
24V input models
17 VDC
48V input models
34 VDC
12V input models
-0.7 25 VDC
Input Surge Voltage (1000ms)
24V input models
-0.7 50 VDC
48V input models
-0.7 100 VDC
Reverse Polarity Input Current
All models
0.5 A
Reflected Ripple Current
See Table
Short Circuit Input Power
All models
2500 mW
Input Filter
All models
Pi Filter
OUTPUT (Vo)
Output Voltage Range
See Table
Output Voltage Accuracy
±0.6 ±1.2 %
Output Voltage Balance
Dual Output, Balanced Loads
±0.5 ±2.0 %
Load Regulation
Io = 10% to 100%
±0.5 ±1.2 %
Load Regulation (2.5V output only)
Io = 10% to 100%
±0.7 ±1.5 %
Line Regulation
Vin = Min to Max
±0.3 ±1.0 %
Output Power
10 W
Output Current Range
See Table
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Line, Load, and Temperature
50 85 mVpk-pk
100
mVpk-pk
15 mVrms
Transient Recovery Time
25% Load Step Change
250 500 µs
Transient Response Deviation
25% Load Step Change
±3 ±5 %
Temperature Coefficient
±0.01 ±0.02 %/°C
PROTECTION
Over Power Protection
110 150 180 %
Short Circuit Protection
Continuous
12V input models
2000mA Slow-Blow Type
Input Fuse Recommendation
24V input models
1000mA Slow-Blow Type
48V input models
500mA Slow-Blow Type
GENERAL
Efficiency
See Table
Switching Frequency
400 KHz
Isolation Voltage Rated
60 seconds
1500
VDC
Isolation Voltage Test
Flash Tested for 1 second
1650
VDC
Isolation Resistance
500VDC
1000
M
Isolation Capacitance
100KHz, 1V
1000 1200 pF
Maximum Capacitive Load
See Table
Internal Power Dissipation
2500 mW
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797

1 page




LANK pdf
LANK 10W Series
2:1 Wide Input Range
Single and Dual Output
10 Watt DC/DC Converter
DESIGN & FEATURE CONSIDERATONS
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source
impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a
capacitor at the input to ensure startup.
By using a good quality low Equivalent Series Resistance (ESR < 1.0at 100kHz) capacitor of 12µF for the 12V
www.DaitnaSphuetetd4eUv.ciocmes, a 4.7µF for the 24V input devices, and a 2.2µF for the 48V input devices. A capacitor mounted
close to the power module helps ensure stability of the unit.
Maximum Capacitive Load
The LANK 10W Series has a limitation of maximum connected capacitance on the output. The power module
may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum
capacitance can be found in the “Output Voltage / Current Rating Chart.”
Over Current Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting
circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit
shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Over Voltage Protection
The Output over voltage clamp consists of control circuitry, which is independent of the primary regulation loop
that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point
than the primary loop. This provides a redundant voltage control that reduces the risk of output over voltage.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the
module, and board spacing. To avoid exceeding the maximum temperature rating of the components inside the
power module, the case temperature must be kept below 95°C. The derating curves are determined from
measurements obtained in an experimental apparatus.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797

5 Page










PáginasTotal 8 Páginas
PDF Descargar[ Datasheet LANK.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
LAN0019-01SMARTDAA V.90 LOW PROFILE TRANSFORMERETC
ETC
LAN0066-50SMART-DAA TransformerLinkCom
LinkCom
LAN0066-52SMART-DAA TransformerLinkCom
LinkCom
LAN3007-8010/100/1000BASE-T Magnetics ModuleLinkCom
LinkCom

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices