MITSUBISHI GCT (Gate Commutated Turn-off) THYRISTOR UNIT
GCU04AA-130
HIGH POWER INVERTER USE
PRESS PACK TYPE
q Symmetrical GCT unit
q GCT and gate driver are connected
q ITQRM: Repetitive controllable on-state current ........ 400A
q IT(AV): Average on-state current ..................... 180A
q VDRM: Repetitive peak off-state voltage ....... 6500V
q VRRM: Repetitive peak reverse voltage ........ 6500V
q Tj: Operation junction temperature ......... 125°C
APPLICATION
Current source inverters, DC choppers, Induction heaters, DC to DC converter
OUTLINE DRAWING
Dimensions in mm
www.DataSheet4U.com
(208)
(104)
φ38±0.2 (68)
(170)
(R39.5)
(20)
9MAX
GATE TEST POINT
CATHODE TEST POINT
LED4 : POWER SUPPLY OK (GREEN)
LED3 : G-K OK (GREEN)
LED2 : GATE ON (YELLOW)
LED1 : GATE OFF (RED)
20V POWER SUPPLY INPUT
(MSTB2.5/2-G-5.08AU)
FIBER OPTIC INPUT (HFBR-2521)
FAULT SIGNAL OUTPUT (HFBR-1521)
(5)
(37)
6±0.5
160MIN
(120)
6±0.5
20±1V
12
6±0.5
φ38±0.2
6±0.5
Mar. 2004
|
|
Note 1. Status signal
1. Status signal from LED
(1) Status signal
Status of GCT
On state
Off state
LED 1
(Red)
OFF
ON
MITSUBISHI GCT (Gate Commutated Turn-off) THYRISTOR UNIT
GCU04AA-130
HIGH POWER INVERTER USE
PRESS PACK TYPE
LED 2
(Yellow)
ON
OFF
(2) Fault signal
Status
Normal
Fault
Fault
Fault
G-K
Normal
Normal
G-K short
G-K short
Power Supply
20±1V
Voltage down
20±1V
Voltage down
G-K LED (LED 3)
(Green)
On
Off
Off
Off
PS LED (LED 4)
(Green)
On
Off
On
Off
2. Status signal from Transmitter
(1) Normal operation
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
L
NL
L
NL
L
NL
(3) Fault signal (G-K short)
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
NL
NL
L
Normal
L
L
NL
Fault
(L : Light NL : No light)
(2) Fault signal (O/V or U/V)
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
L
NL
L
NL
L
L
NL
Normal
Fault
(4) Fault signal (fiber optic)
Control signal
(Control board)
NL
L
Control signal
(GDU input)
Status signal
(GDU output)
NL
L
(Always No light)
(Always light)
Mar. 2004
Preview 5 Page |
Part DetailsOn this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for GCU04AA-130 electronic component. |
Information | Total 6 Pages | |
Link URL | [ Copy URL to Clipboard ] | |
Download | [ GCU04AA-130.PDF Datasheet ] |
Share Link :
Electronic Components Distributor
An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists. |
SparkFun Electronics | Allied Electronics | DigiKey Electronics | Arrow Electronics |
Mouser Electronics | Adafruit | Newark | Chip One Stop |
Featured Datasheets
Part Number | Description | MFRS |
GCU04AA-130 | The function is HIGH POWER INVERTER USE PRESS PACK TYPE. Mitsubishi Electric | |
Semiconductors commonly used in industry:
1N4148 |  
BAW56 |
1N5400 |
NE555 | | ||
Quick jump to:
GCU0
1N4
2N2
2SA
2SC
74H
BC
HCF
IRF
KA |