RoHS Compliant Multimode SFP Transceiver for GbE and Fiber
Channel
FEATURES
z Compliant with SFP Transceiver SFF-8472
MSA specification with internal calibration
z Compliant with Specifications for IEEE
802.3z/Gigabit Ethernet
z Compliant with the 1.0625GBd Fiber Channel
FC-PI 100-M5-SN-I Rev.13
z Single + 3.3V Power Supply and TTL Logic
Interface
z EEPROM with Serial ID Functionality
z Laser Class 1 Product which comply with the
requirements of IEC 60825-1 and IEC 60825-2
z Duplex LC Connector interface
Description
Applications
The LCP-1250A series are hot pluggable 3.3V z Gigabit Ethernet
Small-Form-Factor transceiver modules desigwnwwe.DdataSheezt4U.cSomwitch to Switch interface
expressly for high-speed communication z Switched backplane applications
applications that require rates up to 1.25Gb/s.
The transceiver is data rate transparent, which
means it can support GbE (1.25Gb/s) as well as
1x Fiber channel (1.062Gb/s) operations
The LCP-1250 series are designed to be
z File server interface
Performance
z 850nm VCSEL Link up to 550m in 50/125μm
Multi Mode Fiber
compliant with SFF-8472 SFP Multi-source
Agreement (MSA) with digital diagnostic
monitoring functions: Temperature, VCC, TX
optical power, TX laser bias current, and RX
received optical power.
The post-amplifier of the LCP-1250 series
also includes a Loss of Signal (LOS) circuit that
provides a TTL logic-high output when the
received optical level is below a preset LOS
Assert threshold.
DELTA ELECTRONICS, INC.
1
Oct., 2006
Rev. 6F
www.deltaww.com

1 page




LCP-1250A pdf
Notes:
1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10Kresistor on the host
board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind.
Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.
2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module
with a 4.7 – 10 K resistor. Its states are:
Low (0 – 0.8V):
Transmitter on
(>0.8, < 2.0V):
Undefined
High (2.0 – 3.465V): Transmitter Disabled
Open:
Transmitter Disabled
3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10Kresistor on the
host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded
by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for
serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID
4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10Kresistor.
Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is
below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In
the low state, the output will be pulled to < 0.8V.
5) VeeR and VeeT may be internally connected within the SFP module.
6) RD-/+: These are the differential receiver outputs. They are AC coupled 100differential lines which should be
terminated with 100(differential) at the user SERDES. The AC coupling is done inside the module and is thus
not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential
(185 – 1000 mV single ended) when properly terminated.
7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP
connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown
below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage
at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot
plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the
steady state value. VccR and VccT may be internally connected within the SFP transceiver module.
8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200
mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 –
600 mV single-ended) be used for best EMI performance.
DELTA ELECTRONICS, INC.
5
Oct., 2006
Rev. 6F
www.deltaww.com

5 Page





LCP-1250A arduino
9) Byte 128 to 255 had been set hex 00.
Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address
00-01
02-03
04-05
06-07
08-09
10-11
12-13
14-15
16-17
18-19
20-21
22-23
24-25
26-27
28-29
30-31
32-33
34-35
36-37
38-39
40-45
56-91
92-94
95
96-97
98-99
100-101
102-103
104-105
106-109
110
111
112-119
#
Bytes
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
16
36
3
1
2
2
2
2
2
4
1
1
8
Name
Temp High Alarm
Temp Low Alarm
Temp High Warning
Temp Low Warning
Voltage High Alarm
Voltage Low Alarm
Voltage High Warning
Voltage Low Warning
Bias High Alarm
Bias Low Alarm
Bias High Warning
Bias Low Warning
TX Power High Alarm
TX Power Low Alarm
TX Power High Warning
TX Power Low Warning
RX Power High Alarm
RX Power Low Alarm
RX Power High Warning
RX Power Low Warning
Reversed
External Calibration Constants
Reversed
Checksum
Real Time Temperature
Real Time Supply Voltage
Real Time Tx Bias Current
Real Time Tx Optical Power
Real Time Rx Received Power
Reserved
Optional Status/ Control Bits
Reserved
Optional Set of Alarm and Warning
Value (Dec.)
TC (MAX.)+15
TC (MIN.)
TC (MAX.)+10
TC (MIN.)+10
Vcc+5%
Vcc-5%
Vcc+3%
Vcc-3%
IOP+10
IOP-5
IOP+7
IOP-3
P+3
P-3
P+2
P-2
P0+3
PS-2
P0+2
PS
Notes:
1) TC: Case Operating temperature
2) IOP: Operating current at room temperature. The min. setting current is 0 mA.
3) P: Operating optical power of transmitter at room temperature.
4) P0: Overload optical power of receiver
PS: Sensitivity optical power of receiver
5) Byte 95 contains the low order 8bits of sum of bytes 0-94
Unit
Volt
mA
dBm
dBm
Note
1
2
3
4
5
6
7
DELTA ELECTRONICS, INC.
11
Oct., 2006
Rev. 6F
www.deltaww.com

11 Page







PáginasTotal 14 Páginas
PDF Descargar[ Datasheet LCP-1250A.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
LCP-1250ARoHS Compliant Multimode SFP TransceiverDelta Electronics
Delta Electronics
LCP-1250BRoHS Compliant Small Form Factor Pluggable TransceiverDelta Electronics
Delta Electronics
LCP-1250DRoHS Compliant Single Mode SFP TransceiverDelta Electronics
Delta Electronics
LCP-1250RJ3SR-SRoHS Compliant Copper Small Form-factor Pluggable (SFP) TransceiverDelta Electronics
Delta Electronics

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar