DataSheetWiki


CD20CDW fiches techniques PDF

Teledyne Relays - (CD2xCxx) DC Soild State Relay

Numéro de référence CD20CDW
Description (CD2xCxx) DC Soild State Relay
Fabricant Teledyne Relays 
Logo Teledyne Relays 





1 Page

No Preview Available !





CD20CDW fiche technique
www.DataSheet4U.com
Series CD
2A, 60Vdc Optically Isolated, Short-Circuit Protected
DC Solid-State Relay
Part*
Number
DESC Drawing Relay Description
Number
CD00CFW
CD00CFY
CD01CFW
90091-008
Basic Solid-State Relay (SSR)
SSR with Control Status
CD01CFY 90091-006
CD20CDW
SSR with Short-Circuit Protection
CD20CDY 90091-004
CD21CDW
SSR with Short-Circuit Protection
CD21CDY 90091-002
and Control Status
* The Y suffix denotes parameters tested to MIL-PRF-28750 specifications.
The W suffix denotes parameters tested to Teledyne specifications.
For surface mount (SMT), add “S” prefix to part number. Example:
SCD00CFW
ELECTRICAL SPECIFICATIONS
FEATURES
• Available with short circuit/current
overload protection
• Available with input status monitor
• TTL and CMOS compatible control
• Low ON resistance power FET output
• Fast switching speed
• Meets 28 Vdc system requirements of
MIL-STD-704
• Optical isolation
• Low profile hermetic ceramic package
• Built and tested to the requirements of
MIL-PRF-28750
(-55°C TO +105°C UNLESS OTHERWISE NOTED)
DESCRIPTION
INPUT (CONTROL) SPECIFICATION
When used in 2 terminal configuration
This all solid-state relay utilizes the
latest technology to provide a low ON
(TTL or direct control) (See Fig. 1)
Min Typ Max Units
resistance. The control (input) and load
(output) are optically isolated to protect
Input Current @ VIN = 5 Vdc (See Fig. 2)
14 15 mA
input logic circuits from voltage and
current transients which can occur on
Turn-Off Voltage (Guaranteed Off)
1.5 Vdc
the output supply. The optical isolation
also provides a full floating output, thus
Turn-On Voltage (Guaranteed On)
3.8
allowing the load to be connected to
Vdc either output terminal. The control circuit
Reverse Voltage Protection
-32 Vdc
is buffered to enable the relay to be
driven directly from standard CMOS or
Input Supply Range (See Note 4)
3.8
6 Vdc
open collector TTL logic circuits.
Available options include short circuit
INPUT (CONTROL) SPECIFICATION
and current overload protection, which
provides complete protection for both
When used in 3 terminal configuration
the relay and the system wiring. This
(CMOS or open collector TTL) (See Fig. 1) Min Typ Max Units
omControl Current
.cVCONTROL = 5 Vdc
V = 18 Vdc
CONTROL
250 µA
1 mA
t4UControl Voltage Range
0 18 Vdc
eBias Supply Voltage (See Note 4)
3.8
6 Vdc
heBias Supply Current @ VBIAS = 5 Vdc
STurn-Off Voltage (Guaranteed Off)
14 15 mA
3.2 Vdc
taTurn-On Voltage (Guaranteed On)
0.3 Vdc
feature not only provides protection
should a short or overload occur while
the relay is on, but will also provide
protection should the relay be switched
into a short. In either case, the relay will
sense the short circuit condition and
then block it indefinitely until the short is
removed and the unit is reset by cycling
the input control. The second option is a
status output, which provides a built-in-
test function. This feature checks the
input circuitry of the relay and provides a
logic (0) low when the input circuit is
turned on and operational. Both options
are available either together or
separately as standard features.
www.Da© 2002 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
CD 41
CD\072002\Q1

PagesPages 4
Télécharger [ CD20CDW ]


Fiche technique recommandé

No Description détaillée Fabricant
CD20CDW (CD2xCxx) DC Soild State Relay Teledyne Relays
Teledyne Relays
CD20CDY (CD2xCxx) DC Soild State Relay Teledyne Relays
Teledyne Relays

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche