DataSheet.es    


PDF V23057 Data sheet ( Hoja de datos )

Número de pieza V23057
Descripción Card Relay
Fabricantes Siemens 
Logotipo Siemens Logotipo



Hay una vista previa y un enlace de descarga de V23057 (archivo pdf) en la parte inferior de esta página.


Total 8 Páginas

No Preview Available ! V23057 Hoja de datos, Descripción, Manual

Card Relay E (KRE)
V23057
PCB relay for DC voltage,
neutral, monostable
Features
q Used as a switching element for electrical separation
between low-power control circuits and power load
circuits
q Clearance/creepage distances between winding and
contact 4 mm (A/B version, make contact or change-
over contact) or 8 mm (C/D version, make contact or
break contact)
q Mechanical and electrical characteristics comply with the
“Rules for electrical relays in power installations” (VDE
0435/9.72)
q Used for safe electrical insulation in the following appli-
cations
– open and closed-loop control equipment for domestic
use (VDE 0631)
– electronic equipment for domestic use
(VDE 0860)
q Suitable for fully automated processing
Typical applications
q Machine tool control
q Interface modules
q Timer relays
q Elevator controls
Design
– Flat or upright versions
with 1 changeover contact
or
1 make contact
or
1 break contact
– Changeover contact assembly with single or double con-
tacts
– For printed circuit assembling
– Immersion cleanable
Approvals
VDE
VDE
Mark of conformity 5146
SEV 91.1 12262.04
CSA File LR 89731
UL File E 48393
Siemens AG3

1 page




V23057 pdf
Card Relay E (KRE)
Coil data
Nominal voltages
Nominal power consumption, typ.
Maximum pull-in power
Minimum release voltage
From 6 V– to 60 V–
Special voltages on request
450 ... 500 mW
240 mW
10 % of nominal voltage
Coil versions
Nominal voltage
Unom
V–
6
12
24
48
60
Operating voltage range
at 20 °C
Operate voltage UI
V–
Max. voltage UII
V–
4.2 10.6
8.3 21.5
16.8 40.0
33.6 79.0
42.0 98.0
Resistance
at 20 °C
80 ±
330 ±
1200 ±
4700 ±
7200 ±
8
33
180
700
1080
Number of coil
Ordering code, block 2
001
002
006
013
023
Other coil versions available on request
Data for operating range and class of operative range according to DIN IEC 255 Part 1-00/VDE 435 Part 205 available on
request
UI = Operate voltage at 20 °C after pre-energizing with
UI without contact current
UII = Maximum continuous voltage at 20 °C for
Tc max = 115 °C without contact loading
Operating voltage limits UI and UII depend on temperature and
can be calculated by:
UI tamb = kI · UI 20 °C and UII tamb =kII· UII 20 °C
tamb =
UI tamb =
UII tamb=
kI a. kII =
Tc max =
Ambient temperature
Minimum voltage at ambient temperature tamb
Maximum voltage at ambient temperature tamb
Factors (dependent on temperature), see diagram
Maximum coil temperature
kI
kII
Siemens AG7
Ambient temperature tamb

5 Page










PáginasTotal 8 Páginas
PDF Descargar[ Datasheet V23057.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
V23054Cradle RelayTyco
Tyco
V23057Card RelaySiemens
Siemens
V23057(V23057 / V23127)ETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar